Mostra el registre parcial de l'element
dc.contributor.author | ATLAS Collaboration | |
dc.contributor.author | Castillo Giménez, María Victoria | |
dc.contributor.author | Ferrer Soria, Antonio | |
dc.contributor.author | Fuster Verdú, Juan A. | |
dc.contributor.author | García García, Carmen | |
dc.contributor.author | González de la Hoz, Santiago | |
dc.contributor.author | Hernández Jiménez, Yesenia | |
dc.contributor.author | Higón Rodríguez, Emilio | |
dc.contributor.author | Lacasta Llácer, Carlos | |
dc.contributor.author | Martí García, Salvador | |
dc.contributor.author | Ros Martínez, Eduardo | |
dc.contributor.author | Salt Cairols, José | |
dc.contributor.author | Sanchis Lozano, Miguel Ángel | |
dc.contributor.author | Valls Ferrer, Juan Antonio | |
dc.contributor.author | Villaplana Pérez, Miguel | |
dc.date.accessioned | 2014-05-14T13:28:41Z | |
dc.date.available | 2014-05-14T13:28:41Z | |
dc.date.issued | 2010 | |
dc.identifier.citation | Atlas Collaboration Castillo Giménez, María Victoria Ferrer Soria, Antonio Fuster Verdú, Juan A. García García, Carmen González de la Hoz, Santiago Hernández Jiménez, Yesenia Higón Rodríguez, Emilio Lacasta Llácer, Carlos Martí García, Salvador Ros Martínez, Eduardo Salt Cairols, José Sanchis Lozano, Miguel Angel Valls Ferrer, Juan Antonio Villaplana Pérez, Miguel 2010 Drift Time Measurement in the ATLAS Liquid Argon Electromagnetic Calorimeter using Cosmic Muons European Physical Journal C 70 3 755 785 | |
dc.identifier.uri | http://hdl.handle.net/10550/35192 | |
dc.description.abstract | The ionization signals in the liquid argon of the ATLAS electromagnetic calorimeter are studied in detail using cosmic muons. In particular, the drift time of the ionization electrons is measured and used to assess the intrinsic uniformity of the calorimeter gaps and estimate its impact on the constant term of the energy resolution. The drift times of electrons in the cells of the second layer of the calorimeter are uniform at the level of 1.3 % in the barrel and 2.8 % in the endcaps. This leads to an estimated contribution to the constant term of (0.29 +0.05 -0.04) % in the barrel and (0.54 +0.06 -0.04) % in the endcaps. The same data are used to measure the drift velocity of ionization electrons in liquid argon, which is found to be 4.61 +- 0.07 mm/\mu s at 88.5 K and 1 kV/mm. | |
dc.relation.ispartof | European Physical Journal C, 2010, vol. 70, num. 3, p. 755-785 | |
dc.subject | Partícules (Física nuclear) | |
dc.subject | Detectors de radiació | |
dc.subject | Acceleradors de partícules | |
dc.title | Drift Time Measurement in the ATLAS Liquid Argon Electromagnetic Calorimeter using Cosmic Muons | |
dc.type | journal article | es_ES |
dc.date.updated | 2014-05-14T13:28:41Z | |
dc.identifier.doi | 10.1140/epjc/s10052-010-1403-6 | |
dc.identifier.idgrec | 061926 | |
dc.rights.accessRights | open access | es_ES |
dc.identifier.url | 10.1140/epjc/s10052-010-1403-6 |