Mostra el registre parcial de l'element
dc.contributor.author | ATLAS Collaboration | |
dc.contributor.author | Salt Cairols, José | |
dc.contributor.author | Higón Rodríguez, Emilio | |
dc.contributor.author | González de la Hoz, Santiago | |
dc.contributor.author | Castillo Giménez, María Victoria | |
dc.contributor.author | Ferrer Soria, Antonio | |
dc.contributor.author | Hernández Jiménez, Yesenia | |
dc.contributor.author | García García, Carmen | |
dc.contributor.author | Martí García, Salvador | |
dc.contributor.author | Lacasta Llácer, Carlos | |
dc.contributor.author | Valls Ferrer, Juan Antonio | |
dc.contributor.author | Villaplana Pérez, Miguel | |
dc.date.accessioned | 2014-05-22T10:01:27Z | |
dc.date.available | 2014-05-22T10:01:27Z | |
dc.date.issued | 2010 | |
dc.identifier.citation | The Atlas Collaboration Salt Cairols, Carlos Higón Rodríguez, Emilio González de la Hoz, Santiago Castillo Giménez, María Victoria Ferrer Soria, Antonio Hernández Jiménez, Yesenia García García, Carmen Ferrer, Antonio Martí García, Salvador Lacasta Llácer, Carlos Valls Ferrer, Juan Antonio Villaplana Pérez, Miguel 2010 The ATLAS Inner Detector commissioning and calibration European Physical Journal C 70 3 787 821 | |
dc.identifier.uri | http://hdl.handle.net/10550/35363 | |
dc.description.abstract | The ATLAS Inner Detector is a composite tracking system consisting of silicon pixels, silicon strips and straw tubes in a 2 T magnetic field. Its installation was completed in August 2008 and the detector took part in data- taking with single LHC beams and cosmic rays. The initial detector operation, hardware commissioning and in-situ calibrations are described. Tracking performance has been measured with 7.6 million cosmic-ray events, collected using a tracking trigger and reconstructed with modular pattern-recognition and fitting software. The intrinsic hit efficiency and tracking trigger efficiencies are close to 100%. Lorentz angle measurements for both electrons and holes, specific energy-loss calibration and transition radiation turn-on measurements have been performed. Different alignment techniques have been used to reconstruct the detector geometry. After the initial alignment, a transverse impact parameter resolution of 22.1+/-0.9 {\mu}m and a relative momentum resolution {\sigma}p/p = (4.83+/-0.16) \times 10-4 GeV-1 \times pT have been measured for high momentum tracks. | |
dc.relation.ispartof | European Physical Journal C, 2010, vol. 70, num. 3, p. 787-821 | |
dc.subject | Detectors de radiació | |
dc.title | The ATLAS Inner Detector commissioning and calibration | |
dc.type | journal article | es_ES |
dc.date.updated | 2014-05-22T10:01:27Z | |
dc.identifier.doi | 10.1140/epjc/s10052-010-1366-7 | |
dc.identifier.idgrec | 061994 | |
dc.rights.accessRights | open access | es_ES |
dc.identifier.url | 10.1140/epjc/s10052-010-1366-7 |