NAGIOS: RODERIC FUNCIONANDO

A comparison of different irrigation systems and gravitational effect on final extrusion of the irrigant

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

A comparison of different irrigation systems and gravitational effect on final extrusion of the irrigant

Mostra el registre parcial de l'element

dc.contributor.author Uzunoglu, Emel es
dc.contributor.author Gorduysus, Melahat es
dc.contributor.author Görduysus, Ömer es
dc.date.accessioned 2015-06-29T11:46:24Z
dc.date.available 2015-06-29T11:46:24Z
dc.date.issued 2015 es
dc.identifier.citation Uzunoglu, Emel ; Gorduysus, Melahat ; Görduysus, Ömer. A comparison of different irrigation systems and gravitational effect on final extrusion of the irrigant . En: Journal of Clinical and Experimental Dentistry, 2015, Vol. 7, No. 2: 218-223 es
dc.identifier.uri http://hdl.handle.net/10550/44838
dc.description.abstract Background: The aim of this study was to compare manual needle irrigation (MNI), RinsEndo (RE), and passive ultrasonic irrigation (PUI), and assess the effect of gravity on extrusion from the apex in vitro. Material and Methods: The distobuccal roots of molars were used and the canals were instrumented up to F2. Teeth were mounted on models, which permitted visualization and manipulation of the apices for necessary procedures. The models were placed in articulator to simulate the jaw. Six groups (G) were formed as: G1, G2 and G3 represented mandibular positioning of teeth and were irrigated with MNI, RE, and PUI, respectively, while G4, G5, and G6 represented maxillary positioning of teeth and were also irrigated in same sequence. Prior to the final irrigation, 72 cube-shaped foam pieces covered with aluminum foil were weighed and the values were recorded as the initial weights. The cubes were then placed on the apical part of each sample. Final irrigation was performed with distilled water and the cubes were weighed again to determine their final weights. Data were analyzed using Kruskal-Wallis and Mann-Whitney U post-hoc test ( p <0.05). Results: Irrespective of the irrigation technique used, the amount of irrigant extruded from the apex showed a statistically significant difference related to the effect of gravity ( p <0.05). There was no statistically significant difference between irrigation methods ( p >0.05). When the irrigation systems were compared to examine the effect of gravity, the significant difference was found between G2 and G5 ( p <0.05). Conclusions: Within the limitations of this study, MNI and PUI were found to be reliable irrigation systems. Caution should be exercised when using RinsEndo. en_US
dc.subject Odontología es
dc.subject Ciencias de la salud es
dc.title A comparison of different irrigation systems and gravitational effect on final extrusion of the irrigant es
dc.type journal article es_ES
dc.subject.unesco UNESCO::CIENCIAS MÉDICAS es
dc.type.hasVersion VoR es_ES

Visualització       (1.288Mb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques