NAGIOS: RODERIC FUNCIONANDO

Response of AGATA segmented HPGe detectors to gamma rays up to 15.1 MeV

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Response of AGATA segmented HPGe detectors to gamma rays up to 15.1 MeV

Mostra el registre parcial de l'element

dc.contributor.author AGATA Collaboration
dc.contributor.author Avigo, R.
dc.contributor.author Camera, F.
dc.contributor.author Akkoyun, S.
dc.contributor.author Bazzacco, D.
dc.contributor.author Bellato, Marco
dc.contributor.author Benzoni, G.
dc.contributor.author Blasi, N.
dc.contributor.author Bortolato, D.
dc.contributor.author Bottoni, S.
dc.contributor.author Bracco, A.
dc.contributor.author Brambilla, S.
dc.contributor.author Coelli, S.
dc.contributor.author Gadea Raga, Andrés
dc.date.accessioned 2013-11-29T11:24:46Z
dc.date.available 2013-11-29T11:24:46Z
dc.date.issued 2013
dc.identifier.citation AGATA Collaboration Crespi, F. C. L. Avigo, R. Camera, F. Akkoyun, S. Ataç, A. Bazzacco, D. Bellato, M. Benzoni, G. Blasi, N. Bortolato, D. Bottoni, S. Bracco, A. Brambilla, S. Bruyneel, B. Ceruti, S. Ciemał a, M. Coelli, S. Gadea Raga, Andrés 2013 Response of AGATA segmented HPGe detectors to gamma rays up to 15.1 MeV Nuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors and Associated Equipment 705 47 54
dc.identifier.uri http://hdl.handle.net/10550/31492
dc.description.abstract The response of AGATA segmented HPGe detectors to gamma rays in the energy range 2-15 MeV was measured. The 15.1 MeV gamma rays were produced using the reaction d(B-11,n gamma)C-12 at E-beam=19.1 MeV, while gamma rays between 2 and 9 MeV were produced using an Am-Be-Fe radioactive source. The energy resolution and linearity were studied and the energy-to-pulse-height conversion resulted to be linear within 0.05%.Experimental interaction multiplicity distributions are discussed and compared with the results of Geant4 simulations. It is shown that the application of gamma-ray tracking allows a suppression of background radiation caused by n-capture in Ge nuclei. Finally the Doppler correction for the 15.1 MeV gamma line, performed using the position information extracted with Pulse-shape analysis is discussed.
dc.relation.ispartof Nuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors and Associated Equipment, 2013, vol. 705, p. 47-54
dc.subject Detectors de radiació
dc.subject Física nuclear
dc.title Response of AGATA segmented HPGe detectors to gamma rays up to 15.1 MeV
dc.type journal article es_ES
dc.date.updated 2013-11-29T11:24:46Z
dc.identifier.doi 10.1016/j.nima.2012.12.084
dc.identifier.idgrec 084377
dc.rights.accessRights open access es_ES
dc.identifier.url 10.1016/j.nima.2012.12.084

Visualització       (892.7Kb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques