Mostra el registre parcial de l'element
dc.contributor.author | BABAR Collaboration | |
dc.contributor.author | Martínez Vidal, Fernando | |
dc.contributor.author | Oyanguren Campos, Arantza | |
dc.contributor.author | Villanueva Pérez, Pablo | |
dc.date.accessioned | 2014-04-01T11:28:00Z | |
dc.date.available | 2014-04-01T11:28:00Z | |
dc.date.issued | 2013 | |
dc.identifier.citation | BABAR Collaboration Martínez Vidal, Fernando Oyanguren Campos, Arantza Villanueva Pérez, Pablo 2013 Time-integrated luminosity recorded by the BABAR detector at the PEP-II e(+)e(-) collider Nuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors and Associated Equipment 726 203 213 | |
dc.identifier.uri | http://hdl.handle.net/10550/33934 | |
dc.description.abstract | We describe a measurement of the time-integrated luminosity of the data collected by the BABAR experiment at the PEP-II asymmetric-energy e(+)e(-) collider at the Upsilon(4S), Upsilon(3S), and Upsilon(2S) resonances and in a continuum region below each resonance. We measure the time-integrated luminosity by counting e(+)e(-)-> e(+)e(-) and (for the Upsilon(4S) only) e(+)e(-)->mu(+)mu(-) candidate events, allowing additional photons in the final state. We use data-corrected simulation to determine the cross-sections and reconstruction efficiencies for these processes, as well as the major backgrounds. Due to the large cross-sections of e(+)e(-)-> e(+)e(-) and e(+)e(-)->mu(+)mu(-), the statistical uncertainties of the measurement are substantially smaller than the systematic uncertainties. The dominant systematic uncertainties are due to observed differences between data and simulation, as well as uncertainties on the cross-sections. For data collected on the Upsilon(3S) and Upsilon(2S) resonances, an additional uncertainty arises due to Upsilon -> e(+)e(-)X background. For data collected off the Upsilon resonances, we estimate an additional uncertainty due to time dependent efficiency variations, which can affect the short off-resonance runs. The relative uncertainties on the luminosities of the on-resonance (off-resonance) samples are 0.43% (0.43%) for the Upsilon(4S), 0.58% (0.72%) for the Upsilon(3S), and 0.68% (0.88%) for the Upsilon(2S). | |
dc.relation.ispartof | Nuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors and Associated Equipment, 2013, vol. 726, p. 203-213 | |
dc.subject | Física nuclear | |
dc.title | Time-integrated luminosity recorded by the BABAR detector at the PEP-II e(+)e(-) collider | |
dc.type | journal article | es_ES |
dc.date.updated | 2014-04-01T11:28:00Z | |
dc.identifier.doi | 10.1016/j.nima.2013.04.029 | |
dc.identifier.idgrec | 091099 | |
dc.rights.accessRights | open access | es_ES |
dc.identifier.url | 10.1016/j.nima.2013.04.029 |