NAGIOS: RODERIC FUNCIONANDO

Accuracy combining different brands of implants and abutments

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Accuracy combining different brands of implants and abutments

Mostra el registre parcial de l'element

dc.contributor.author Solá Ruiz, María Fernanda es
dc.contributor.author Selva Otaolaurruchi, Eduardo J. es
dc.contributor.author Senent Vicente, Gisela es
dc.contributor.author González de Cossio, Inés es
dc.contributor.author Amigó Borrás, Vicente es
dc.date.accessioned 2014-05-29T07:05:00Z
dc.date.available 2014-05-29T07:05:00Z
dc.date.issued 2013 es
dc.identifier.citation Solá Ruiz, María Fernanda ; Selva Otaolaurruchi, Eduardo ; Senent Vicente, Gisela ; González de Cossio, Inés ; Amigó Borrás, Vicente. Accuracy combining different brands of implants and abutments. En: Medicina oral, patología oral y cirugía bucal. Ed inglesa, 2013, Vol. 18, No. 2: 332-336 es
dc.identifier.uri http://hdl.handle.net/10550/35594
dc.description.abstract Objective: To evaluate the vertical misfit between different brands of dental implants and prosthetic abutments, with or without mechanical torque, and to study their possible combination. Study design: Five different brands of implant were used in the study: Biofit (Castemaggiore, Italy), Bioner S.A. (Barcelona, Spain), 3i Biomet (Palm Beach, U.S.A.), BTI (Alava, Spain) and Nobel Biocare (Göteborg, Sweden), with standard 4.1 mm heads and external hexagons, and their respective machined prosthetic abutments. The implant-to- abutment fit/misfit was evaluated at four points (vestibular, lingual/palatine, mesial and distal) between implants and abutments of the same brand and different brands, with or without mechanical torque, using SEM micrographs at 5000X. Image analysis was performed using NIS-Elements software (Nikon Instruments Europe B.V.). Results: Before applying torque, vertical misfit (microgaps) of the different combinations tested varied between 1.6 and 5.4 microns and after applying torque, between 0.9 and 5.9 microns, an overall average of 3.46±2.96 microns. For manual assembly without the use of mechanical torque, the best results were obtained with the com - bination of the 3i implant and the BTI abutment. The Nobel implant and Nobel abutment, 3i-3i and BTI-BTI and the combination of 3i implant with BTI or Nobel abutment provided the best vertical fit when mechanical torque was applied. Conclusions: The vertical fits obtained were within the limits considered clinically acceptable. The application of mechanical torque improved outcomes. There is compatibility between implants and abutments of different brand and so their combination is a clinical possibility. en_US
dc.subject Odontología es
dc.subject Ciencias de la salud es
dc.title Accuracy combining different brands of implants and abutments es
dc.type journal article es_ES
dc.subject.unesco UNESCO::CIENCIAS MÉDICAS es
dc.type.hasVersion VoR es_ES

Visualització       (1.193Mb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques