Three-year clinical performance of two indirect composite inlays compared to direct composite restorations

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Three-year clinical performance of two indirect composite inlays compared to direct composite restorations

Mostra el registre parcial de l'element

dc.contributor.author Ozakar Ilday, Nurcan es
dc.contributor.author Zorba, Yahya Orçun es
dc.contributor.author Yildiz, Mehmet es
dc.contributor.author Erdem, Vildan es
dc.contributor.author Seven, Nilgun es
dc.contributor.author Demirbuga, Sezer es
dc.date.accessioned 2014-05-29T07:05:46Z
dc.date.available 2014-05-29T07:05:46Z
dc.date.issued 2013 es
dc.identifier.citation Ozakar Ilday, Nurcan ; Zorba, Yahya Orçun ; Yildiz, Mehmet ; Erdem, Vildan ; Seven, Nilgun ; Demirbuga, Sezer. Three-year clinical performance of two indirect composite inlays compared to direct composite restorations. En: Medicina oral, patología oral y cirugía bucal. Ed inglesa, 2013, Vol. 18, No. 3: 521-528 es
dc.identifier.uri http://hdl.handle.net/10550/35608
dc.description.abstract Objective: Despite the incremental build-up of resin composite restorations, their polymerization shrinkage during curing presents a serious problem. Indirect composite resin systems represent an alternative in overcoming some of the deficiencies of direct composite restorations. The hypothesis of the present study states that the clinical performance of restorations may be affected by different generation and application techniques. Study Design: Sixty restorations (20 DI system (Coltène/Whaledent AG, Altstätten, Switzerland) composite inlays, 20 Tescera ATL system (BISCO Inc. Schaumburg, Illinois, USA) composite inlays, and 20 direct composites) were applied to premolar teeth in 49 patients. Restorations were clinically evaluated by two examiners. Data were analyzed using the Kruskal-Wallis, Mann-Whitney U, Wilcoxon Signed Ranks, and X2 tests. Results: The Tescera ATL system performed significantly better than both direct composite restorations (p<0.001) and DI system (p<0.05). Conclusion: Within the limitations of this 3-year clinical study, indirect resin restorations showed better scores than direct restorations. In addition, the Tescera ATL system was found to be more successful than the DI system and direct composite restorations. en_US
dc.subject Odontología es
dc.subject Ciencias de la salud es
dc.title Three-year clinical performance of two indirect composite inlays compared to direct composite restorations es