Dental implants placed on bone subjected to vertical alveolar distraction show the same performance as those placed on primitive bone
Mostra el registre complet de l'element
Visualització
(998.7Kb)
|
|
|
|
|
|
Pérez Sayáns, Mario; León Camacho, María De Los Ángeles; Somoza Martín, José Manuel; Fernández González, Beatriz; Blanes-Vázquez-Gundín, Silvia; Gándara Rey, José Manuel; García García, Abel
|
|
Aquest document és un/a article, creat/da en: 2013
|
|
|
|
Introduction: Vertical osteogenic alveolar distraction (VOAD) allows for the augmentation of the alveolar ridge
for the placement of dental implants in atrophic alveolar ridges. The goal of this paper is to assess long-term peri-
implant bone resorption in implants placed on bones subjected to VOAD, comparing it with a group of patients
who had implants placed directly on the alveolar bone without previous bone regeneration.
Material and Methods: We conducted a follow-up study on 32 patients who were divided into two groups: The
Distraction Group (14 patients), and the Distraction-Free Group (18 patients), who received a total of 100 implants.
Peri-implant bone loss was measured by means of panoramic X-rays, at the time of loading and one year later, and
in 35 implants of each group after 3 years of functional loading.
Results: The peri-implant bone resorption (PBR) average observed in the Distraction Group at the time of prosthetic placement is higher (0.50±0.09 mm) than in the Distraction-Free Group (0.25±0.06 mm), showing statistically significant results (p=0.047). PBR levels 1 year after loading were the same for both groups (0.66 mm). At 3
years, they were higher in the Distraction Group (1.03 ± 0.22 mm vs. 0.68 ± 0.08 mm).
|
|
Veure al catàleg Trobes
|
Aquest element apareix en la col·lecció o col·leccions següent(s)