Mostra el registre parcial de l'element
dc.contributor.author | Herrero Climent, Mariano | es |
dc.contributor.author | Santos García, Rocío | es |
dc.contributor.author | Jaramillo Santos, Reyes | es |
dc.contributor.author | Romero Ruiz, Manuel María | es |
dc.contributor.author | Fernández Palacín, Ana | es |
dc.contributor.author | Lázaro Calvo, Pedro | es |
dc.contributor.author | Bullón, Pedro | es |
dc.contributor.author | Ríos Santos, José Vicente | es |
dc.date.accessioned | 2014-07-04T07:51:46Z | |
dc.date.available | 2014-07-04T07:51:46Z | |
dc.date.issued | 2013 | es |
dc.identifier.citation | Herrero Climent, Mariano ; Santos García, Rocío ; Jaramillo Santos, Reyes ; Romero Ruiz, Manuel María ; Fernández Palacín, Ana ; Lázaro Calvo, Pedro ; Bullón, Pedro ; Ríos Santos, José Vicente. Assessment of Osstell ISQ's reliability for implant stability measurement: a cross-sectional clinical study. En: Medicina oral, patología oral y cirugía bucal. Ed inglesa, 2013, Vol. 18, No. 6: 877-882 | es |
dc.identifier.uri | http://hdl.handle.net/10550/36831 | |
dc.description.abstract | Resonance frequency analysis (RFA) allows assess implant stability by measuring implant oscillation frequency on the bone. RFA is an objective and non-invasive method for implant stability measurement, although scarce evidence has been provided so far on its reliability. Objectives: Assess the Osstell ISQ system's reliability (i.e., its measurement reproducibility and repeatability) by means of the intraclass correlation coefficient (ICC) as statistical method. Study Desing: Implants stability registers were completed by means of Osstell ISQ on 85 implants on 23 patients. Six measurements were completed on each implant by means of two different SmartPegs (types I and II); that is, three consecutive measurements with each transducer. Results: Average ISQ was 72.40, 72.22 and 72.79, and 72.06, 72.59 and 72.82 in the first, second, and third measurements with SmartPegs I and II, respectively. Equal values or differences below three ISQ points were observed in 52.9% and 62.4% of the cases with SmartPegs I and II, respectively. The intraclass correlation coefficient was 0.97 for both SmartPegs, and repeatability and reproducibility also reached 0.97 for both SmartPegs. Conclusions: The RFA system Osstell ISQ presents almost perfect repeatability and reproducibility after intraclass correlation coefficient analysis. Osstell ISQ measurements are highly reliable regarding reproducibility. Therefore, one measurement proves enough. | en_US |
dc.subject | Odontología | es |
dc.subject | Ciencias de la salud | es |
dc.title | Assessment of Osstell ISQ's reliability for implant stability measurement: a cross-sectional clinical study | es |
dc.type | journal article | es_ES |
dc.subject.unesco | UNESCO::CIENCIAS MÉDICAS | es |
dc.type.hasVersion | VoR | es_ES |
dc.identifier.url | http://www.medicinaoral.com/pubmed/medoralv18_i6_p877.pdf | es |