NAGIOS: RODERIC FUNCIONANDO

Evaluation of Dentaport ZX and Raypex 6 electronic apex locators: an in vivo study

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Evaluation of Dentaport ZX and Raypex 6 electronic apex locators: an in vivo study

Mostra el registre parcial de l'element

dc.contributor.author Moscoso, Saddy es
dc.contributor.author Pineda, Kenneth es
dc.contributor.author Basilio, Juan es
dc.contributor.author Alvarado, Carlos es
dc.contributor.author Roig Cayón, Miguel es
dc.contributor.author Duran Sindreu, Fernando es
dc.date.accessioned 2014-07-04T07:54:36Z
dc.date.available 2014-07-04T07:54:36Z
dc.date.issued 2014 es
dc.identifier.citation Moscoso, Saddy ; Pineda, Kenneth ; Basilio, Juan ; Alvarado, Carlos ; Roig Cayón, Miguel ; Duran Sindreu, Fernando. Evaluation of Dentaport ZX and Raypex 6 electronic apex locators: an in vivo study. En: Medicina oral, patología oral y cirugía bucal. Ed inglesa, 2014, Vol. 19, No. 2: 202-205 es
dc.identifier.uri http://hdl.handle.net/10550/36870
dc.description.abstract Med Oral Patol Oral Cir Bucal. 2014 Mar 1;19 (2):e202-5. Evaluation of Dentaport ZX and Raypex 6: An in vivo study e202 Journal section: Clinical and Experimental Dentistry Publication Types: Research Evaluation of Dentaport ZX and Raypex 6 electronic apex locators: An in vivo study Saddy Moscoso 1 , Kenneth Pineda 1 , Juan Basilio 1 , Carlos Alvarado 2 , Miguel Roig 2 , Fernando Duran- Sindreu 3 1 MD, Department of Restorative Dentistry and Endodontics, Universitat Internacional de Catalunya, Barcelona, Spain 2 MD, DDS, PhD, Department of Restorative Dentistry and Endodontics, Universitat Internacional de Catalunya, Barcelona, Spain 3 Department of Restorative Dentistry and Endodontics, Universitat Internacional de Catalunya, Barcelona, Spain Correspondence: Dentistry Faculty Universitat Internacional de Catalunya C/Josep Trueta s/n. 08195 Sant Cugat del Vallès, Spain fduranst@hotmail.com Received: 10/02/2013 Accepted: 04/05/2013 Abstract Introduction: Raypex 6 is an electronic apex locator (EAL) that has not yet been tested in vivo. The purpose of this in vivo study was to compare the accuracy of two EALs: the Dentaport ZX and the Raypex 6. Material and Methods: The study involved 36 straight single-rooted teeth. A 10-K file was advanced until the EAL detected the major foramen. The file was fixed in a replaceable pattern of light-cured composite. The apical part of each canal was trimmed to expose the file tip. The distances from the file tips to the major foramen were measured. Results: Wilcoxon's signed Rank test found no significant differences between the Dentaport ZX and Raypex 6 in terms of their abilities to detect the major foramen (P = .52) The Dentaport ZX was accurate 82.35% of the time to ± 0.5 mm and 97.05% of the time to ± 1 mm, whereas the Raypex 6 was accurate 88.22% of the time to ± 0.5 mm and 100% of the time to ± 1 mm. Conclusions: No statistically significant differences were observed between the performance of the Dentaport ZX and Raypex 6 EALs under the in vivo clinical conditions used in this study. en_US
dc.subject Odontología es
dc.subject Ciencias de la salud es
dc.title Evaluation of Dentaport ZX and Raypex 6 electronic apex locators: an in vivo study es
dc.type journal article es_ES
dc.subject.unesco UNESCO::CIENCIAS MÉDICAS es
dc.type.hasVersion VoR es_ES
dc.identifier.url http://www.medicinaoral.com/pubmed/medoralv19_i2_p202.pdf es

Visualització       (311.9Kb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques