Técnica de Ender y tornillo-placa deslizante a compresión en el tratamiento de las fracturas trocantéreas
Mostra el registre complet de l'element
Visualització
(43.09Kb)
|
|
|
|
|
|
Pérez Aznar, A. T.; Cebrián Gómez, Román; Sebastiá Forcada, Emilio; Sanz Reig, J.
|
|
Aquest document és un/a article, creat/da en: 1998
|
|
|
|
A comparative study on 195 throchanttric hip fractures treated Esther by Ender's mailing (112 cases) and slidding screw-plate (83 cases) were performed. There were no statistically significant differences between the two techniques regarding blood loosening. The slidding screw-plate showed better functional results, except in cases over 80 years old where both techniques were found to be similar. Ender's nailing disclosed a higher number of mechanical and reoperations.Se realizó un estudio comparativo de 195 fracturas troncantéreas del fémur tratadas quirúrgicamente de las que 112 lo fueron mediante enclavado endomedular de Ender y 83 mediante tornillo-placa deslizante a compresión (TPDC). No encontramos diferencias significativas de las pérdidas sanguíneas entre las dos técnicas. El TPDC presentó mejores resultados funcionales salvo en pacientes mayores de 80 años en que son similares ambas técnicas. El enclavado Ender presentó mayor número de complicaciones mecánicas y reintervenciones. |
|
Veure al catàleg Trobes
|
Aquest element apareix en la col·lecció o col·leccions següent(s)