Mostra el registre parcial de l'element
dc.contributor.author | Arenas Planelles, Antonio | es |
dc.contributor.author | Tejero Ibáñez, Alberto | es |
dc.contributor.author | Garbayo Marturet, Antonio Jesús | es |
dc.contributor.author | Arias Nieto, F. J. | es |
dc.date.accessioned | 2014-12-02T13:06:51Z | |
dc.date.available | 2014-12-02T13:06:51Z | |
dc.date.issued | 2001 | es |
dc.identifier.citation | Arenas Planelles, Antonio ; Tejero Ibáñez, Alberto ; Garbayo Marturet, Antonio Jesús ; Arias Nieto, F. J.. Fractura compleja de la parte proximal del húmero secundaria a descarga eléctrica. En: Revista española de cirugía osteoarticular, 2001, Volumen 36, Número 205: 42-44 | es |
dc.identifier.uri | http://hdl.handle.net/10550/40431 | |
dc.description.abstract | A case of comminuted fracture of proximal humerus following electrical injury (380 volts) is reported. The treatment was surgical. A satisfactory result was obtained, without pain or functional impairment of the limb. | en_US |
dc.description.abstract | Se presenta un caso de fractura compleja de parte proximal de húmero secundaria a una descarga eléctrica de 380 voltios. Fue tratado quirúrgicamente, consiguiéndose un resultado funcional satisfactorio, sin dolor ni alteración funcional de la extremidad. | es |
dc.subject | Medicina clínica | es |
dc.subject | Ciencias de la salud | es |
dc.title | Fractura compleja de la parte proximal del húmero secundaria a descarga eléctrica | es |
dc.type | journal article | es_ES |
dc.subject.unesco | UNESCO::CIENCIAS MÉDICAS | es |
dc.type.hasVersion | VoR | es_ES |