Influence of surface preparation on fracture load of resin composite-based repairs
Mostra el registre complet de l'element
Visualització
(1.069Mb)
|
|
|
|
|
|
Agustín Panadero, Rubén; Mateos Palacios, Rocío; Román Rodríguez, Juan Luis; Solá Ruiz, María Fernanda; Fons Font, Antonio
|
|
Aquest document és un/a article, creat/da en: 2015
|
|
|
|
The purpose of the present study is to evaluate the fracture load of composite-based repairs to fractured zirconium
oxide (Z) crowns and to ceramic-fused-to-metal (CM) crowns, comparing different mechanical surface preparation
methods. A total of 75 crowns were repaired; samples then underwent dynamic loading and thermocycling. Final
fracture load values for failure of the repaired crowns were measured and the type of fracture registered. Group I:
CM: Surface preparation with a diamond bur + 9.5% Hydrofluoric Acid (HF) etching; Group II): CM: air-particle
(Al
2
O
3
) + 9.5% HF; Group III: CM: Silica coating (SiO
2
); Group IV): Z: air-particle (Al
2
O
3
) + HF 9.5%; Group
V) Z: Silica coating (SiO
2
). Of the three CM groups, Group I (CM-diamond bur) showed the highest mean failure
value, with significant difference in comparison with Group III (CM-silica coating). For the zirconia groups, the
highest value was obtained by Group V (silica coating).
|
|
Veure al catàleg Trobes
|
Aquest element apareix en la col·lecció o col·leccions següent(s)
Mostra el registre complet de l'element