NAGIOS: RODERIC FUNCIONANDO

Absolute momentum calibration of the HARP TPC

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Absolute momentum calibration of the HARP TPC

Mostra el registre parcial de l'element

dc.contributor.author HARP Collaboration
dc.contributor.author Catanesi, Maria Gabriella
dc.contributor.author Burguet Castell, Jordi
dc.contributor.author Cervera Villanueva, Anselmo
dc.contributor.author Gómez Cadenas, Juan José
dc.contributor.author Martín-Albo Simón, Justo
dc.contributor.author Novella Garijo, Pau
dc.contributor.author Sorel, Michel
dc.date.accessioned 2015-12-21T10:49:46Z
dc.date.available 2015-12-21T10:49:46Z
dc.date.issued 2008
dc.identifier.citation HARP Collaboration Catanesi, Maria Gabriella Burguet Castell, Jordi Cervera Villanueva, Anselmo Gómez Cadenas, Juan José Martín-Albo Simón, Justo Novella Garijo, Pau Sorel, Michel 2008 Absolute momentum calibration of the HARP TPC Journal Of Instrumentation 3 P04007
dc.identifier.uri http://hdl.handle.net/10550/49662
dc.description.abstract In the HARP experiment the large-angle spectrometer is using a cylindrical TPC as main tracking and particle identification detector. The momentum scale of reconstructed tracks in the TPC is the most important systematic error for the majority of kinematic bins used for the HARP measurements of the double-differential production cross-section of charged pions in proton interactions on nuclear targets at large angle. The HARP TPC operated with a number of hardware shortfalls and operational mistakes. Thus it was important to control and characterize its momentum calibration. While it was not possible to enter a direct particle beam into the sensitive volume of the TPC to calibrate the detector, a set of physical processes and detector properties were exploited to achieve a precise calibration of the apparatus. In the following we recall the main issues concerning the momentum measurement in the HARP TPC, and describe the cross-checks made to validate the momentum scale. As a conclusion, this analysis demonstrates that the measurement of momentum is correct within the published precision of 3%.
dc.language.iso eng
dc.relation.ispartof Journal Of Instrumentation, 2008, vol. 3, p. P04007
dc.subject Física
dc.title Absolute momentum calibration of the HARP TPC
dc.type journal article es_ES
dc.date.updated 2015-12-21T10:49:46Z
dc.identifier.doi 10.1088/1748-0221/3/04/P04007
dc.identifier.idgrec 069887
dc.rights.accessRights open access es_ES

Visualització       (2.276Mb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques