NAGIOS: RODERIC FUNCIONANDO

First results of the Instrumentation Line for the deep-sea ANTARES neutrino telescope

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

First results of the Instrumentation Line for the deep-sea ANTARES neutrino telescope

Mostra el registre parcial de l'element

dc.contributor.author ANTARES Collaboration
dc.contributor.author Aguilar Sánchez, Juan Antonio
dc.contributor.author Hernández Rey, Juan José
dc.contributor.author Real Máñez, Diego
dc.contributor.author Roca Blay, Víctor
dc.contributor.author Salesa Greus, Francisco
dc.contributor.author Zornoza Gómez, Juan de Dios
dc.contributor.author Zúñiga Román, Juan
dc.date.accessioned 2016-05-25T11:24:39Z
dc.date.available 2016-05-25T11:24:39Z
dc.date.issued 2006
dc.identifier.citation ANTARES Collaboration Aguilar Sánchez, Juan Antonio Hernández Rey, Juan José Real Máñez, Diego Roca Blay, Víctor Salesa Greus, Francisco Zornoza Gómez, Juan de Dios Zúñiga Román, Juan 2006 First results of the Instrumentation Line for the deep-sea ANTARES neutrino telescope Astroparticle Physics 26 4-5 314 324
dc.identifier.uri http://hdl.handle.net/10550/53740
dc.description.abstract In 2005, the ANTARES Collaboration deployed and operated at a depth of 2500 m a so-called Mini Instrumentation Line equipped with Optical Modules (MILOM) at the ANTARES site. The various data acquired during the continuous operation from April to December 2005 of the MILOM confirm the satisfactory performance of the Optical Modules, their front-end electronics and readout system. as well as the calibration devices of the detector. The in situ measurement of the Optical Module time response yields a resolution better than 0.5 ns. The performance of the acoustic positioning system, which enables the spatial reconstruction of the ANTARES detector with a precision of about 10 cm, is verified. These results demonstrate that with the full ANTARES neutrino telescope the design angular resolution of better than 0.3 degrees can be realistically achieved.
dc.language.iso eng
dc.relation.ispartof Astroparticle Physics, 2006, vol. 26, num. 4-5, p. 314-324
dc.subject Física nuclear
dc.title First results of the Instrumentation Line for the deep-sea ANTARES neutrino telescope
dc.type journal article es_ES
dc.date.updated 2016-05-25T11:24:40Z
dc.identifier.doi 10.1016/j.astropartphys.2006.07.004
dc.identifier.idgrec 039430
dc.rights.accessRights open access es_ES

Visualització       (3.184Mb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques