Mostra el registre parcial de l'element
dc.contributor.author | Prat Pastor, Jaime | es |
dc.contributor.author | Comín Clavijo, Mario | es |
dc.contributor.author | Dejoz, Ricardo | es |
dc.contributor.author | Peris Serra, José Luis | es |
dc.contributor.author | Atienza Vicente, Carlos M. | es |
dc.contributor.author | Vera Luna, Pedro | es |
dc.date.accessioned | 2016-10-21T07:02:57Z | |
dc.date.available | 2016-10-21T07:02:57Z | |
dc.date.issued | 1995 | es |
dc.identifier.citation | Prat Pastor, Jaime ; Comín Clavijo, Mario ; Dejoz, Ricardo ; Peris Serra, José Luis ; Atienza Vicente, Carlos M. ; Vera Luna, Pedro. Criterios biomecánicos de diseño de un nuevo sistema de fijación externa: Stronger® . En: Revista española de cirugía osteoarticular, 1995, Volumen 30, Número 178: 169-175 | es |
dc.identifier.uri | http://hdl.handle.net/10550/55458 | |
dc.description.abstract | Se presenta el desarrollo de un nuevo sistema de fijación externa basado en estudios de investigación aplicada, cuyos resultados se han plasmado en criterios de diseño clínicos y biomecánicos. Los aspectos novedosos contemplados se refieren a un aumento de la rigidez del montaje en base a la fijación y el dentado de las rótulas de articulación. Asimismo, se facilita la técnica quirúrgica mediante el taladrado y colocación de las agujas sin la utilización de plantillas y la posibilidad de corregir desplazamientos en el foco fractuario de forma independiente en los tres planos del espacio. Finalmente, se ha diseñado un sistema de monitorización, acoplable al fijador, para caracterizar mecánicamente el callo de fractura durante el período de consolidación. | es |
dc.description.abstract | A new external fixation system has been designed based on previous applied research studies. The design criteria generated were focused on both clinical and biomechanical aspects. An increase in frame stiffness was obtained by means of an independent fixation system of the pins, clamp sleeves and striated hinges. Furthermore, surgical technique has been simplified by means of independent adjustment in the three space planes of movement. The use of a previous guide fixator for drilling and pin insertion was eliminated. Finally, a strain gauge monitoring system has been developed to characterize mechanical callus features during fracture healing. | en_US |
dc.subject | Medicina clínica | es |
dc.subject | Ciencias de la salud | es |
dc.title | Criterios biomecánicos de diseño de un nuevo sistema de fijación externa: Stronger® | es |
dc.type | journal article | es_ES |
dc.subject.unesco | UNESCO::CIENCIAS MÉDICAS | es |
dc.type.hasVersion | VoR | es_ES |