The authors are studied by ultrasonography 112 newborns (224
hips) with clinical signs of congenital dysplasia and dislocation of
the hip. The results obtained are compared with clinical findings
and radiographic study emphasizing the diagnostic limitations of
the clasics maneuvistes of physical examination and radiography.
They conclude that the ultrasonography is the most sure method
and innocuous to the early diagnosis of the congenital dysplasia
and dislocation of the hip at the newborn.Se estudian mediante ultrasonografía las caderas de 112 recién nacidos
(224 caderas) con signos clínicos de displasia luxante de cadera. Los resultados
se comparan con los datos de exploración clínica y estudio radiográ-
fico poniendo en evidencia las limitaciones diagnósticas de las maniobras
exploratorias clásicas y la radiografía. Concluye que la ultrasonografía es
el método más seguro e inocuo para el diagnóstico precoz de la displasia
luxante de cadera en el recién nacido. |
|