NAGIOS: RODERIC FUNCIONANDO

Measurements of total ozone amount over Badajoz (Southwestern Spain) by means of a GUV multiband radiometer

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Measurements of total ozone amount over Badajoz (Southwestern Spain) by means of a GUV multiband radiometer

Mostra el registre parcial de l'element

dc.contributor.author Bogeat, J. A.
dc.contributor.author Piedehierro, A. A.
dc.contributor.author Serrano, A.
dc.contributor.author Cancillo, M. L.
dc.contributor.author Obregón, M. A.
dc.contributor.author Benítez Suárez, Rafael
dc.date.accessioned 2017-07-03T08:25:13Z
dc.date.available 2017-07-03T08:25:13Z
dc.date.issued 2012
dc.identifier.citation Bogeat, J. A. Piedehierro, A. A. Serrano, A. Cancillo, M. L. Obregón, M. A. Benítez Suárez, Rafael 2012 Measurements of total ozone amount over Badajoz (Southwestern Spain) by means of a GUV multiband radiometer Óptica Pura y Aplicada 45 1 39 43
dc.identifier.uri http://hdl.handle.net/10550/59305
dc.description.abstract The Ultraviolet Index (UVI) obtained by a multichannel radiometer GUV‐2511 (Biospherical Instruments Inc.) is analyzed in this paper. This instrument has been recently installed in the radiometric station of Extremadura University in Badajoz (Spain). The UV Index has been calculated by a linear combination of three and four GUV channel irradiance values. In order to test these results, simultaneous values of UVI were calculated with the data provided by a well calibrated broadband UVS‐E‐T instrument colocated side by side the GUV multichannel. This radiometer has a spectral response that is adapted to the erythemal (sunburn) action spectrum of the human skin. One‐minute simultaneous values of both instruments have been used to calculate ultraviolet Index (UVI). Although the measurement period is limited, it covers all sky conditions, from cloud‐free to overcast days. UVI calculated with the whole data set by both methods are well correlated, but not as well as using only clear day data. It was observed that GUV underestimates UVI values (mean bias error, MBE=18.9%), being the four channel method the most successful.
dc.language.iso eng
dc.relation.ispartof Óptica Pura y Aplicada, 2012, vol. 45, num. 1, p. 39-43
dc.subject Òptica
dc.title Measurements of total ozone amount over Badajoz (Southwestern Spain) by means of a GUV multiband radiometer
dc.type journal article es_ES
dc.date.updated 2017-07-03T08:25:14Z
dc.identifier.doi 10.7149/OPA.45.1.39
dc.identifier.idgrec 119777
dc.rights.accessRights open access es_ES

Visualització       (331.8Kb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques