Bonding to silicate ceramics : conventional technique compared with a simplified technique
Mostra el registre complet de l'element
Visualització
(473.5Kb)
|
|
|
|
|
|
Román Rodríguez, Juan Luis; Alonso Pérez Barquero, Jorge; González Angulo, Eva; Fons Font, Antonio; Bustos Salvador, José Luis
|
|
Aquest document és un/a article, creat/da en: 2017
|
|
|
|
Silicate ceramic bonding is carried out by acid-etching with hydrofluoric acid (HF) followed by an application of silane. By replacing HF with ammonium polyfluoride, contained in the same flask as the silane, the number of steps in this clinical procedure, can be reduced, while maintaining bond strength values, and reducing toxicity. A shear bond test was performed to compare the conventional and the simplified surface treatment techniques. Twenty ceramic samples were fabricated from IPS emax CAD® ceramic (Ivoclar Vivadent) and divided into two groups (G1 and G2) (n=10). The conventional technique was applied to G1 samples, and the simplified technique to G2 samples. A resin cement cylinder was bonded to each sample. Afterwards, samples underwent shear bond strength testing in a universal test machine. G1 obtained 26.53±6.33 MPa and G2 23.52±8.41 MPa, without statistically significant differences between the two groups. Monobond Etch Prime appears to obtain equivalent results in terms of bond strength while simplifying the technique. Further investigation is required to corroborate these preliminary findings.
|
|
Veure al catàleg Trobes
|
|
|
Aquest element apareix en la col·lecció o col·leccions següent(s)
Mostra el registre complet de l'element