NAGIOS: RODERIC FUNCIONANDO

Effect of EndoActivator and Er,Cr:YSGG laser activation of Qmix, as final endodontic irrigant, on sealer penetration: a confocal microscopic study

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Effect of EndoActivator and Er,Cr:YSGG laser activation of Qmix, as final endodontic irrigant, on sealer penetration: a confocal microscopic study

Mostra el registre parcial de l'element

dc.contributor.author Chaudhry, Sarika es
dc.contributor.author Yadav, Sudha es
dc.contributor.author Talwar, Sangeeta es
dc.contributor.author Verma, Mahesh es
dc.date.accessioned 2017-07-18T12:21:28Z
dc.date.available 2017-07-18T12:21:28Z
dc.date.issued 2017 es
dc.identifier.citation Chaudhry, Sarika ; Yadav, Sudha ; Talwar, Sangeeta ; Verma, Mahesh. Effect of EndoActivator and Er,Cr:YSGG laser activation of Qmix, as final endodontic irrigant, on sealer penetration: a confocal microscopic study. En: Journal of Clinical and Experimental Dentistry. 2017. Vol. 9, no. 2: 218 es
dc.identifier.uri http://hdl.handle.net/10550/59620
dc.description.abstract Through chemomechanical debridement of the root canal is a primary requisite for successful endodontic therapy. Thus the aim of this study was to evaluate the effects of using QmiX alone, QmiX with EndoActivator and QmiX with Er,Cr:YSGG laser for final irrigation on sealer penetration into the dentinal tubules. 75 extracted human mandibular premolar teeth were treated with sodium hypochlorite (NaOCl) irrigation. The samples were divided into 5 groups according to the final irrigation solution used: (1) 17% EDTA and 2.5% NaOCl, (2) QmiX (3) QmiX with Er,Cr:YSGG laser and (4) QmiX with EndoActivator (5) 2.5%NaOCl. All teeth were obturated using cold lateral condensation technique with gutta percha and AH 26 sealer (Dentsply; DeTrey,Konstanz, Germany) labeled with Rhodamine B dye. The teeth were sectioned at distances of 2 and 5 from root apex. Total percentage and maximum depth of sealer penetration were measured using confocal laser scanning microscopy. Results of one way Anova analysis showed that there was a significant difference in the percentage and depth of sealer penetration among all groups at 3 and 5 mm level sections (P < .05). Within the groups maximum sealer penetration was recorded for Er,Cr:YSGG laser activated group. Greater depth of sealer penetration was recorded at 5mm as compared to 3mm in all the groups. Activation of QMix using EndoActivator and Er,Cr:YSGG laser enhanced the sealer penetration at apical and middle third. Thus Er,Cr:YSGG laser and EndoActivator may act as an appropriate adjunct during chemomechanical preparation of the root canal. en_US
dc.subject Odontología es
dc.subject Ciencias de la salud es
dc.title Effect of EndoActivator and Er,Cr:YSGG laser activation of Qmix, as final endodontic irrigant, on sealer penetration: a confocal microscopic study es
dc.type journal article es_ES
dc.subject.unesco UNESCO::CIENCIAS MÉDICAS es
dc.type.hasVersion VoR es_ES

Visualització       (1.297Mb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques