Mostra el registre parcial de l'element
dc.contributor.author | Chaudhry, Sarika | es |
dc.contributor.author | Yadav, Sudha | es |
dc.contributor.author | Talwar, Sangeeta | es |
dc.contributor.author | Verma, Mahesh | es |
dc.date.accessioned | 2017-07-18T12:21:28Z | |
dc.date.available | 2017-07-18T12:21:28Z | |
dc.date.issued | 2017 | es |
dc.identifier.citation | Chaudhry, Sarika ; Yadav, Sudha ; Talwar, Sangeeta ; Verma, Mahesh. Effect of EndoActivator and Er,Cr:YSGG laser activation of Qmix, as final endodontic irrigant, on sealer penetration: a confocal microscopic study. En: Journal of Clinical and Experimental Dentistry. 2017. Vol. 9, no. 2: 218 | es |
dc.identifier.uri | http://hdl.handle.net/10550/59620 | |
dc.description.abstract | Through chemomechanical debridement of the root canal is a primary requisite for successful endodontic therapy. Thus the aim of this study was to evaluate the effects of using QmiX alone, QmiX with EndoActivator and QmiX with Er,Cr:YSGG laser for final irrigation on sealer penetration into the dentinal tubules. 75 extracted human mandibular premolar teeth were treated with sodium hypochlorite (NaOCl) irrigation. The samples were divided into 5 groups according to the final irrigation solution used: (1) 17% EDTA and 2.5% NaOCl, (2) QmiX (3) QmiX with Er,Cr:YSGG laser and (4) QmiX with EndoActivator (5) 2.5%NaOCl. All teeth were obturated using cold lateral condensation technique with gutta percha and AH 26 sealer (Dentsply; DeTrey,Konstanz, Germany) labeled with Rhodamine B dye. The teeth were sectioned at distances of 2 and 5 from root apex. Total percentage and maximum depth of sealer penetration were measured using confocal laser scanning microscopy. Results of one way Anova analysis showed that there was a significant difference in the percentage and depth of sealer penetration among all groups at 3 and 5 mm level sections (P < .05). Within the groups maximum sealer penetration was recorded for Er,Cr:YSGG laser activated group. Greater depth of sealer penetration was recorded at 5mm as compared to 3mm in all the groups. Activation of QMix using EndoActivator and Er,Cr:YSGG laser enhanced the sealer penetration at apical and middle third. Thus Er,Cr:YSGG laser and EndoActivator may act as an appropriate adjunct during chemomechanical preparation of the root canal. | en_US |
dc.subject | Odontología | es |
dc.subject | Ciencias de la salud | es |
dc.title | Effect of EndoActivator and Er,Cr:YSGG laser activation of Qmix, as final endodontic irrigant, on sealer penetration: a confocal microscopic study | es |
dc.type | journal article | es_ES |
dc.subject.unesco | UNESCO::CIENCIAS MÉDICAS | es |
dc.type.hasVersion | VoR | es_ES |