NAGIOS: RODERIC FUNCIONANDO

Comparative cytotoxicity evaluation of eight root canal sealers

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Comparative cytotoxicity evaluation of eight root canal sealers

Mostra el registre parcial de l'element

dc.contributor.author Poggio, Claudio es
dc.contributor.author Riva, Paolo es
dc.contributor.author Chiesa, Marco es
dc.contributor.author Colombo, Marco es
dc.contributor.author Pietrocola, Giampiero es
dc.date.accessioned 2017-07-19T06:50:11Z
dc.date.available 2017-07-19T06:50:11Z
dc.date.issued 2017 es
dc.identifier.citation Poggio, Claudio ; Riva, Paolo ; Chiesa, Marco ; Colombo, Marco ; Pietrocola, Giampiero. Comparative cytotoxicity evaluation of eight root canal sealers. En: Journal of Clinical and Experimental Dentistry, 9 4 2017: 574-578 es
dc.identifier.uri http://hdl.handle.net/10550/59656
dc.description.abstract The aim of the present study is to evaluate and compare the cytotoxic effects of eight root canal sealers (BioRoot RCS, TotalFill BC Sealer, MTA Fillapex, Sealapex, AH Plus, EasySeal, Pulp Canal Sealer, N2) on immortalized human gingival fibroblasts over a period of 24, 48 and 72 hours. Immortalized human gingival fibroblast-1 HGF-1 (ATCC CRL-2014) were incubated. Root canal sealers were then placed into sterile, cylindrical Teflon moulds. The extraction was made eluting the sealers in cell culture medium. Cells (1 × 104) were seeded in each well of a 96-well plate and incubated for 24 h at 37°C. Cultures were then exposed to 100 ?L of the extracts medium. The percentage of viable cells in each well was calculated relative to control cells set to 100%. BioRoot RCS and TotalFill BC Sealer extracted for 24h showed no cytotoxic effect, while it was mild by using 48 and 72 h extracts. No cytotoxic effect was measured by using AH Plus medium eluted for 24 h, while it was moderate after 48 h and severe after 72 h. Pulp Canal Sealer, Sealapex and N2 showed moderately cytotoxic activity for all the extraction times. EasySeal and MTA Fillapex remained severely or borderline mildly cytotoxic for all the extraction times. In the present study only BioRoot RCS, TotalFill BC Sealer and AH Plus showed no cytotoxic effects at least in the first 24h. All the other sealers revealed moderately or severely cytotoxic activity during all the extraction times. es
dc.title Comparative cytotoxicity evaluation of eight root canal sealers es
dc.type journal article es_ES
dc.subject.unesco UNESCO::CIENCIAS MÉDICAS es
dc.identifier.doi 10.4317/jced.53724 es
dc.type.hasVersion VoR es_ES

Visualització       (479.1Kb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques