Resonance frequency analysis-reliability in third generation instruments : Osstell mentor ®

Mostra el registre parcial de l'element

dc.contributor.author Herrero Climent, Mariano es
dc.contributor.author Albertini, Matteo es
dc.contributor.author Ríos Santos, José Vicente es
dc.contributor.author Lázaro Calvo, Pedro es
dc.contributor.author Fernández Palacín, Ana es
dc.contributor.author Bullón, Pedro es
dc.date.accessioned 2017-07-24T11:04:30Z
dc.date.available 2017-07-24T11:04:30Z
dc.date.issued 2012 es
dc.identifier.citation Herrero Climent, Mariano ; Albertini, Matteo ; Ríos Santos, José Vicente ; Lázaro Calvo, Pedro ; Fernández Palacín, Ana ; Bullón, Pedro. Resonance frequency analysis-reliability in third generation instruments : Osstell mentor ®. En: Medicina oral, patología oral y cirugía bucal. Ed. inglesa, 17 5 2012: 27- es
dc.identifier.uri http://hdl.handle.net/10550/59890
dc.description.abstract Few studies assess repeatability and reproducibility in registers of resonance frequency analysis (a value of dental implant stability). Objective: Few studies assess repeatability and reproducibility in resonance frequency analyses (implant stability evaluation). This study is aimed at assessing reliability (repeatabilty and reproducibility) in the Osstell Mentor® system using the intraclass correlation coefficient (ICC) as the statistical method. Study Design: ISQ measurements of RFA were carried out by means of the Osstell Mentor ® instrument in 58 implants in 19 patients. Six measurements were performed on each implant by means of two different Smart-Pegs (I and II). Three consecutive measurements were registered with each transducer. Results: Average ISQ varied from 72.43 to 72.60 and 73.26 in the first, second and third measurements, respectively with the SamrtPeg I and from 72.98 to 73.26 and 73.74 in the first, second and third measurements, respectively with the SamrtPeg II . Exactly equal values were observed in 10.43 and 12.1% of the cases with Smart-Pegs I and II, respectively. The intraclass correlation coefficient was 0.96 and 0.96 for Smart Pegs I and II, respectively. Repeatability and reproducibility was 0.97 for both Smart-Pegs I and II. Conclusions: The RFA system contributed by Osstell Mentor ® renders almost perfect reproducibility and repeatability, as proven by statistical analysis carried out by means of ICC with 95% confidence level. This instrument contributes highly reliable RFA measurements in dental implants. es
dc.title Resonance frequency analysis-reliability in third generation instruments : Osstell mentor ® es
dc.type journal article es_ES
dc.subject.unesco UNESCO::CIENCIAS MÉDICAS es
dc.identifier.doi 10.4317/medoral.17861 es
dc.type.hasVersion VoR es_ES

Visualització       (395.3Kb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques