dc.contributor.author | Herrero Climent, Mariano | es |
dc.contributor.author | Albertini, Matteo | es |
dc.contributor.author | Ríos Santos, José Vicente | es |
dc.contributor.author | Lázaro Calvo, Pedro | es |
dc.contributor.author | Fernández Palacín, Ana | es |
dc.contributor.author | Bullón, Pedro | es |
dc.date.accessioned | 2017-07-24T11:04:30Z | |
dc.date.available | 2017-07-24T11:04:30Z | |
dc.date.issued | 2012 | es |
dc.identifier.citation | Herrero Climent, Mariano ; Albertini, Matteo ; Ríos Santos, José Vicente ; Lázaro Calvo, Pedro ; Fernández Palacín, Ana ; Bullón, Pedro. Resonance frequency analysis-reliability in third generation instruments : Osstell mentor ®. En: Medicina oral, patología oral y cirugía bucal. Ed. inglesa, 17 5 2012: 27- | es |
dc.identifier.uri | http://hdl.handle.net/10550/59890 | |
dc.description.abstract | Few studies assess repeatability and reproducibility in registers of resonance frequency analysis (a value of dental implant stability). Objective: Few studies assess repeatability and reproducibility in resonance frequency analyses (implant stability evaluation). This study is aimed at assessing reliability (repeatabilty and reproducibility) in the Osstell Mentor® system using the intraclass correlation coefficient (ICC) as the statistical method. Study Design: ISQ measurements of RFA were carried out by means of the Osstell Mentor ® instrument in 58 implants in 19 patients. Six measurements were performed on each implant by means of two different Smart-Pegs (I and II). Three consecutive measurements were registered with each transducer. Results: Average ISQ varied from 72.43 to 72.60 and 73.26 in the first, second and third measurements, respectively with the SamrtPeg I and from 72.98 to 73.26 and 73.74 in the first, second and third measurements, respectively with the SamrtPeg II . Exactly equal values were observed in 10.43 and 12.1% of the cases with Smart-Pegs I and II, respectively. The intraclass correlation coefficient was 0.96 and 0.96 for Smart Pegs I and II, respectively. Repeatability and reproducibility was 0.97 for both Smart-Pegs I and II. Conclusions: The RFA system contributed by Osstell Mentor ® renders almost perfect reproducibility and repeatability, as proven by statistical analysis carried out by means of ICC with 95% confidence level. This instrument contributes highly reliable RFA measurements in dental implants. | es |
dc.title | Resonance frequency analysis-reliability in third generation instruments : Osstell mentor ® | es |
dc.type | journal article | es_ES |
dc.subject.unesco | UNESCO::CIENCIAS MÉDICAS | es |
dc.identifier.doi | 10.4317/medoral.17861 | es |