NAGIOS: RODERIC FUNCIONANDO

Low energy KTP laser in oral soft tissues surgery : a 52 patients clinical study

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Low energy KTP laser in oral soft tissues surgery : a 52 patients clinical study

Mostra el registre parcial de l'element

dc.contributor.author Fornaini, Carlo es
dc.contributor.author Rocca, Jean Paul es
dc.contributor.author Merigo, Elisabetta es
dc.contributor.author Meleti, Marco es
dc.contributor.author Manfredi, Maddalena es
dc.contributor.author Nammour, Samir es
dc.contributor.author Vescovi, Paolo es
dc.date.accessioned 2017-07-25T12:11:22Z
dc.date.available 2017-07-25T12:11:22Z
dc.date.issued 2012 es
dc.identifier.citation Fornaini, Carlo ; Rocca, Jean Paul ; Merigo, Elisabetta ; Meleti, Marco ; Manfredi, Maddalena ; Nammour, Samir ; Vescovi, Paolo. Low energy KTP laser in oral soft tissues surgery : a 52 patients clinical study. En: Medicina oral, patología oral y cirugía bucal. Ed. inglesa, 17 2 2012: 9- es
dc.identifier.uri http://hdl.handle.net/10550/59988
dc.description.abstract Objectives: Since 1962 laser appliances have been used for soft tissues surgery of oral cavity with significant advantages compared to the traditional instruments: excellent bleeding control, possibility to avoid the use of suture, good patient compliance thanks to a decrease of intra- and post-operative discomfort and biostimulating effect. Unfortunately, the wavelengths so far used have been seen to cause, in association with an excellent ablation capacity, heat damage of the tissues that can decrease healing process and cause a greater discomfort to patients. The aim of this study was to evaluate the laser-assisted KTP laser surgery at low power in terms of characteristics of intervention and patients compliance. Study design: In this study, we describe the application of a new and recently introduced in dentistry wavelength, the KTP laser (532 nm), used with low power (1 Watt - CW), evaluating the time of interventions and, by a Numerical Rating Scale, the intra and postoperative pain. Results: KTP laser used at low power permits to obtain good pain control during operations that were carried out with only a topic anaesthetic (EMLA, Astratech), as shown in VAS tests. Good healing with limited or absent burning areas in treated portion of tissue. Conclusions: These preliminary study allows us to affirm that KTP laser with low parameters permits to perform oral surgery with good pain control and good wound healing. A greater number of clinical cases are however necessary to confirm the result obtained. © Medicina Oral. es
dc.title Low energy KTP laser in oral soft tissues surgery : a 52 patients clinical study es
dc.type journal article es_ES
dc.subject.unesco UNESCO::CIENCIAS MÉDICAS es
dc.identifier.doi 10.4317/medoral.17428 es
dc.type.hasVersion VoR es_ES

Visualització       (1.011Mb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques