NAGIOS: RODERIC FUNCIONANDO

The cytotoxicity of resin composites cured with three light curing units at different curing distances

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

The cytotoxicity of resin composites cured with three light curing units at different curing distances

Mostra el registre parcial de l'element

dc.contributor.author Ergün, Gülfem es
dc.contributor.author Egilmez, Ferhan es
dc.contributor.author Cekic Nagas, Isil es
dc.date.accessioned 2017-07-26T12:32:09Z
dc.date.available 2017-07-26T12:32:09Z
dc.date.issued 2011 es
dc.identifier.citation Ergün, Gülfem ; Egilmez, Ferhan ; Cekic Nagas, Isil. The cytotoxicity of resin composites cured with three light curing units at different curing distances. En: Medicina oral, patología oral y cirugía bucal. Ed. inglesa, 16 2 2011: 23- es
dc.identifier.uri http://hdl.handle.net/10550/60168
dc.description.abstract Objective: The purpose of this study was to compare the effect of light curing distance on the cytotoxicity of five resin composites cured with three high-power light curing units. Study design: Seven cylindrical discs of each material (Grandio ®, Voco; Filtek ? Z250, 3M ESPE; Clearfil ? AP-X, Kuraray Co. Ltd.; Aelite ? LS, Bisco Inc. and Simile ®, Pentron) were cured. For curing, soft-up mode of quartz-tungsten-halogen, exponential mode of light emitting diode for 20 s, and ramp-curing mode of plasma arc light curing units for 6 s were used. The curing tip distances were determined as 2 and 9 mm and controlled via the use of metal rings. After ageing the samples for 24 and 72 hours in Dulbecco?s Modified Eagle Medium/Ham?s F12 (DMEM/F12), cytotoxicity of the extracts to cultured fibroblasts (L 929) was measured by using MTT (tetrazolium salt 3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide) assay. The degree of cytotoxicity for each sample was determined according to the reference value represented by the cells in a pure culture medium. Statistical significance was determined using multifactorial analysis of variance. Results: The type of resin composite (p<0.05), light curing unit (p<0.05), curing tip distance (p<0.05) and evaluation period factor (p<0.05) had statistically significant cytotoxic effects on L?929 mouse fibroblast cells. However, when the tested materials polymerized at both distances (2 mm and 9 mm) in both evaluation periods (24h and 72h), there was no significant difference in the mean CSR% values obtained when the quartz-tungsten-halogen, light emitting diode and plasma arc light curing units were used (p=0.184, F=1.448). Conclusions: The results of this study suggest that the light curing units and resin composites should be harmonized to one another and the curing distance between the tip of the light curing unit and the restoration surface should be as close as possible in order to achieve maximal biocompatibility es
dc.title The cytotoxicity of resin composites cured with three light curing units at different curing distances es
dc.type journal article es_ES
dc.subject.unesco UNESCO::CIENCIAS MÉDICAS es
dc.identifier.doi 10.4317/medoral.16.e252 es
dc.type.hasVersion VoR es_ES

Visualització       (494.2Kb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques