NAGIOS: RODERIC FUNCIONANDO

A novel trephine design for sinus lift lateral approach. Case report

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

A novel trephine design for sinus lift lateral approach. Case report

Mostra el registre parcial de l'element

dc.contributor.author Farré Pagés, Núria es
dc.contributor.author Augé Castro, Mª Luisa es
dc.contributor.author Alaejos Algarra, Fernando es
dc.contributor.author Mareque Bueno, Javier es
dc.contributor.author Ferrés Padró, Eduard es
dc.contributor.author Hernández-Alfaro, Federico es
dc.date.accessioned 2017-07-27T06:48:48Z
dc.date.available 2017-07-27T06:48:48Z
dc.date.issued 2011 es
dc.identifier.citation Farré Pagés, Núria ; Augé Castro, Mª Luisa ; Alaejos Algarra, Fernando ; Mareque Bueno, Javier ; Ferrés Padró, Eduard ; Hernández-Alfaro, Federico. A novel trephine design for sinus lift lateral approach. Case report. En: Medicina oral, patología oral y cirugía bucal. Ed. inglesa, 16 1 2011: 17- es
dc.identifier.uri http://hdl.handle.net/10550/60203
dc.description.abstract Various techniques are described in the literature, either by crestal or lateral approach. Sinus augmentation has a high percentage of success, but presents a number of intraoperative and postoperative complications. The most frequent complication is the Schneiderian membrane perforation with a percentage of perforations between 11% and 56% according to authors. The aim of this study is to describe another membrane approach technique for the sinus lateral wall osteotomy that minimizes the risk of Schneiderian membrane perforation. We present a case of a 50 year old patient attended the University Dental Clinic (UDC) of International University of Catalonia for implant and crown treatment due to the loss of a right maxillary first molar. To insert an implant in position 1.6 a computerized tomography (CT) was requested to determine with greater accuracy the quantity of residual crestal bone. It showed a height of 5 mm and width of 8 mm. The lateral osteotomy was performed with a (SLA KIT® -Neobiotech) trephine mounted in the same implant handpiece with which the field for the implant and the implant itself were prepared. It can be concluded that in the case described, the use of trephine drills of the SLA system mounted in a handpiece allows better access to lateral approach due to its perpendicular position relative to the sinus wall minimizing the membrane perforation risk. es
dc.title A novel trephine design for sinus lift lateral approach. Case report es
dc.type journal article es_ES
dc.subject.unesco UNESCO::CIENCIAS MÉDICAS es
dc.identifier.doi 10.4317/medoral.16.e79 es
dc.type.hasVersion VoR es_ES

Visualització       (325.9Kb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques