Intraorifice sealing ability of different materials in endodontically treated teeth

Mostra el registre parcial de l'element

dc.contributor.author Bailón Sánchez, Mª Estela es
dc.contributor.author González Castillo, Silvia es
dc.contributor.author González Rodríguez, Mª Paloma es
dc.contributor.author Poyatos Martínez, Rafael es
dc.contributor.author Ferrer Luque, Carmen María es
dc.date.accessioned 2017-07-27T06:49:10Z
dc.date.available 2017-07-27T06:49:10Z
dc.date.issued 2011 es
dc.identifier.citation Bailón Sánchez, Mª Estela ; González Castillo, Silvia ; González Rodríguez, Mª Paloma ; Poyatos Martínez, Rafael ; Ferrer Luque, Carmen María. Intraorifice sealing ability of different materials in endodontically treated teeth. En: Medicina oral, patología oral y cirugía bucal. Ed. inglesa, 16 1 2011: 22- es
dc.identifier.uri http://hdl.handle.net/10550/60208
dc.description.abstract Objectives: To evaluate Cavit? G, ProRoot? MTA and Tetric® EvoFlow as intraorifice barriers to prevent coronal microleakage in root canal treatment. Study Design: Forty-two human single rooted teeth were divided randomly in three experimental groups of 10 specimens each and two control groups. The experimental groups were prepared with hand instrumentation and cold lateral condensed technique of the gutta-percha. Four millimetres of coronal gutta-percha were removed and replaced by one of the following filling materials: Cavit? G, Tetric® EvoFlow or ProRoot? MTA. In the experimental groups, leakage was measured by the concentration of leaked glucose in the apical reservoir at 1, 7, 30, and 45 days, using the enzymatic glucose oxidase method. Data were analyzed by means of Mann-Whitney U and Kruskal-Wallis tests at ?=0.05. Results: The glucose penetration results of three experimental groups increased gradually over time. No significant differences were found among groups at 24 hours and 1 week. At thirty and forty-five days, Cavit? and Tetric® EvoFlow values were significantly different (p=0.007 and p=0.023, respectively). Conclusions: The sealing ability of the Cavit? G, ProRoot? MTA and Tetric® EvoFlow used as intraorifice materials tends to be similar over time. es
dc.title Intraorifice sealing ability of different materials in endodontically treated teeth es
dc.type journal article es_ES
dc.subject.unesco UNESCO::CIENCIAS MÉDICAS es
dc.identifier.doi 10.4317/medoral.16.e105 es
dc.type.hasVersion VoR es_ES

Visualització       (376.9Kb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques