Changes in radiological protection and quality control in Spanish dental installations : 1996-2003

Mostra el registre parcial de l'element

dc.contributor.author Alcaraz Baños, Miguel es
dc.contributor.author Parra Pérez, María del Carmen es
dc.contributor.author Armero Barranco, David es
dc.contributor.author Velasco Hidalgo, Francisco es
dc.contributor.author Velasco Hidalgo, Esteban es
dc.date.accessioned 2017-09-07T08:55:22Z
dc.date.available 2017-09-07T08:55:22Z
dc.date.issued 2009 es
dc.identifier.citation Alcaraz Baños, Miguel ; Parra Pérez, María del Carmen ; Armero Barranco, David ; Velasco Hidalgo, Francisco ; Velasco Hidalgo, Esteban. Changes in radiological protection and quality control in Spanish dental installations : 1996-2003. En: Medicina oral, patología oral y cirugía bucal. Ed. inglesa, 14 10 2009: 2- es
dc.identifier.uri http://hdl.handle.net/10550/60597
dc.description.abstract Introduction: The European Union has established specific directives concerning radiological protection which are obligatory for member States. In addition, all Spanish dental clinics with radiological equipment are required to have an annual quality control check. Objective: To analyze the effect of new European legislation on dental radiological practice in Spain and to determine whether it has resulted in lower doses being administered to patients. Material and Methods: A total of 10,171 official radiological quality control reports on Spanish dental clinics, covering 16 autonomous regions, were studied following the passing of Royal Decree 2071/1995 on quality criteria in radiodiagnostic installations. The reports, compiled by U.T.P.R Asigma S.A., a company authorised by the Nuclear Safety Council, cover the years 1996 to 2003, which has enabled us to monitor the evolution of radiological procedures in dental clinics over a seven year period. Results: According to the reports for 2003, 77.3 % of clinics complied with EU requirements, using equipment of 70 kVp, 8 mA, 1.5 mm Al filters, with a collimator length of 20 cm. However, non-compliance was detected in approximately a third (30.8%) of the equipment inspected: alterations in the kilovoltage used, exposure time, performance of the tubing, dosage, linearity/intensity of current and acoustic-luminous signal 6.86%. The mean skin dose reached 3.11 mGy for patients who received an x-ray of an upper molar, representing a decrease of 18% over the seven years studied. Conclusion: there has obviously been a general improvement in the parameters studied, but only 77.3% of the installations complied fully with official EU regulations concerning dental radiological protection. es
dc.title Changes in radiological protection and quality control in Spanish dental installations : 1996-2003 es
dc.type journal article es_ES
dc.subject.unesco UNESCO::CIENCIAS MÉDICAS es
dc.identifier.doi 10.4317/medoral.14.e499 es
dc.type.hasVersion VoR es_ES