Fracture properties of composite-dentin beams bonded with a self?etching adhesive were tested following short term pretreatments to simulate potential degradation mechanisms (thermal cycling, immersion in 5% NaOCl, or fatigue cycling). Beams of rectangular cross-section were shaped to a size of ~0.87 x 0.87 x 10 mm and placed in a four-point bending apparatus, with the loading points 1.8 and 7.2 mm apart, with the interface centered between the inner rollers. Testing was performed in Hanks? Balanced Salt Solution at 25 ?C . Solid dentin and solid composite beams [n = 6] had bending strengths of 164.4 and 164.6 MPa, respectively, under monotonically increasing loads. Bonded beams [n = 6] had strengths of 56.3 MPa. Thermo-cycling (5? to 55?C), NaOCl solution immersion, or 105 of pre-fatigue cycles did not decrease the strength. Conclusion: Thermal stress, exposure to NaOCL, or 105 cycles of mechanical stress does not decrease bond strength of composite bonded to dentin as tested in four-point bending.
|