Mostra el registre parcial de l'element
dc.contributor.author | Martínez Lozano, José Antonio | |
dc.contributor.author | Utrillas Esteban, María Pilar | |
dc.contributor.author | Pedrós Esteban, Roberto | |
dc.contributor.author | Tena Sangüesa, Fernando | |
dc.contributor.author | Cuadra Oyanguren, Jesús de la | |
dc.contributor.author | Pérez-Ferriols, Amparo | |
dc.contributor.author | Aliaga Boniche, Adolfo | |
dc.date.accessioned | 2017-10-24T12:47:20Z | |
dc.date.available | 2017-10-24T12:47:20Z | |
dc.date.issued | 2001 | |
dc.identifier.citation | Martínez Lozano, José Antonio Utrillas Esteban, María Pilar Pedrós Esteban, Roberto Tena Sangüesa, Fernando Cuadra Oyanguren, Jesús de la Pérez Ferriols, Amparo Aliaga Boniche, Adolfo 2001 Algunas evidencias clínicas sobre la necesidad del calibrado de simuladores solares usados en dermatología Actas dermo-sifiliográficas 92 10 444 451 | |
dc.identifier.uri | http://hdl.handle.net/10550/62889 | |
dc.description.abstract | Los simuladores solares emiten una radiación espectral que reproduce con bastante fidelidad el espectro de la radiación solar. Se emplean en dermatología, fundamentalmente en la realización del fototest para la determinación de dosis eritemáticas (MED). Su espectro de emisión puede variar con el tiempo en función del envejecimiento de las fuentes o por desajustes mecánicos u ópticos del sistema, lo que hace obligada una calibración periódica de los mismos. Esta calibración se realiza por medio de espectrorradiómetros de precisión, lo que permite comparar la respuesta espectral en mediciones sucesivas que deberían realizarse en función del tiempo de uso, al menos cada 6 meses. En este trabajo hemos estudiado la respuesta espectral de un simulador Solar Light 12S empleado en el Servicio de Dermatología del Hospital General Universitario de Valencia, encontrándose en el mismo considerables variaciones con el tiempo debido fundamentalmente a desajustes de alineación óptica. Estos desajustes recomiendan sustituir las unidades de tiempo habitualmente aplicadas en los fototests por unidades de energía para la obtención de valores de referencia para los diferentes tipos de piel. Abstract Solar simulators emit a spectral radiation that reproduce very accurately the solar spectrum. They are employed in dermatology mainly to perform the phototests in order to determine eryhemal doses (MED). The emission spectrum of such simulators may change with time as a consequence of the ageing of the sources or owing to the system getting out of mechanical or optical alignment. So it is necessary a periodic calibration of the instrument. Such calibration must be performed by means of precision spectroradiometers allowing the comparison of the spectral response through successive measurements within six months intervals at most. In this work the spectral response of a Solar Light 12S simulator that is employed in the Dermatology Service of the General Hospital of Valencia has been studied. Important variations with time have been found, own mainly to variations in the optical alignment. The time units usually employed in the phototests should be replaced by energy units in order to get the reference values for the different skin types. | |
dc.language.iso | spa | |
dc.relation.ispartof | Actas dermo-sifiliográficas , 2001, vol. 92, num. 10, p. 444-451 | |
dc.subject | Radiació solar | |
dc.subject | Dermatologia | |
dc.title | Algunas evidencias clínicas sobre la necesidad del calibrado de simuladores solares usados en dermatología | |
dc.type | journal article | es_ES |
dc.date.updated | 2017-10-24T12:47:20Z | |
dc.identifier.doi | 10.1016/S0001-7310(01)76537-4 | |
dc.identifier.idgrec | 003812 | |
dc.rights.accessRights | open access | es_ES |