NAGIOS: RODERIC FUNCIONANDO

Updated secondary implant stability data of two dental implant systems. A retrospective cohort study

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Updated secondary implant stability data of two dental implant systems. A retrospective cohort study

Mostra el registre parcial de l'element

dc.contributor.author Grognard, Nicolas es
dc.contributor.author Verleye, Gino es
dc.contributor.author Mavreas, Dimitrios es
dc.contributor.author Vande-Vannet, Bart es
dc.date.accessioned 2017-11-28T11:04:54Z
dc.date.available 2017-11-28T11:04:54Z
dc.date.issued 2017 es
dc.identifier.citation Grognard, Nicolas ; Verleye, Gino ; Mavreas, Dimitrios ; Vande-Vannet, Bart. Updated secondary implant stability data of two dental implant systems. A retrospective cohort study. En: Journal of Clinical and Experimental Dentistry, 9 9 2017: 1121-1128 es
dc.identifier.uri http://hdl.handle.net/10550/63372
dc.description.abstract At present, updated secondary implant stability data generated by actual versions of resonance frequency analysis (RFA) and mobility measurement (MM) electronic devices of 2 different implant systems with actual manufactured surfaces seem to lack and/or are incomplete. Secondary implant stability data based on both RFA and MM measurements were collected and analyzed from 44 formerly treated patients (24 f, 20 m) that received either Ankylos Cellplus (Ø3.5mm) (A) (n=36) or Straumann regular neck SLA tissue level (Ø4.1mm) (S) (n=37) implants in posterior positions of both jawbones (total number= 72). These results were interpretated in view of formerly published data. Estimated RFA outcomes (mean±SD) for A implants were of 81.23 (±0.65) (LP) - 76.15 (±1.57) (UP) isq; for S implants 76.15 (±1.48) (LP) - 73.88 (±2.34) (UP) isq. Estimated MM outcomes for A implants were (-4.0) (±0.23) (LP) - (-3.2) (±0.33) (UP) ptv; for S implants (-5.15) (±0.39) (LP) - (-4.4) (±0.84) (UP) ptv. According to GEE statistical modelling, implant type and ? position seems to influence the outcome variables (p<0.05), gender and implant length did not (p >0.05). Secondary implant stability values, recorded with current RFA and MM devices, of A Cellplus implants are provided for the first time. A difference of 14.7-9.7 isq values was noted for CellPlus versus TPS S implants recorded with a cabled RFA device. This study supports the assumption that RFA outcomes generated with first generation RFA devices are different from those obtained with current RFA devices, meaning that its use in reviews need caution and correction. es
dc.title Updated secondary implant stability data of two dental implant systems. A retrospective cohort study es
dc.type journal article es_ES
dc.subject.unesco UNESCO::CIENCIAS MÉDICAS es
dc.identifier.doi 10.4317/jced.54146 es
dc.type.hasVersion VoR es_ES

Visualització       (479.4Kb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques