NAGIOS: RODERIC FUNCIONANDO

Transportation assessment in simulated curved canals after preparation with twisted file adaptive and bt-race instruments

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Transportation assessment in simulated curved canals after preparation with twisted file adaptive and bt-race instruments

Mostra el registre parcial de l'element

dc.contributor.author Andrade-Junior, Carlos-Vieira es
dc.contributor.author Neto, Nilton Dessaune es
dc.contributor.author Rodrigues, Renata Costa Val es
dc.contributor.author Antunes, Henrique dos Santos es
dc.contributor.author Porpino, Mariana Teixeira Maneschy es
dc.contributor.author Carvalhal, Júlio Cesar A. es
dc.contributor.author Armada, Luciana es
dc.date.accessioned 2017-11-28T11:04:54Z
dc.date.available 2017-11-28T11:04:54Z
dc.date.issued 2017 es
dc.identifier.citation Andrade-Junior, Carlos-Vieira ; Neto, Nilton Dessaune ; Rodrigues, Renata Costa Val ; Antunes, Henrique dos Santos ; Porpino, Mariana Teixeira Maneschy ; Carvalhal, Júlio Cesar A. ; Armada, Luciana. Transportation assessment in simulated curved canals after preparation with twisted file adaptive and bt-race instruments. En: Journal of Clinical and Experimental Dentistry, 9 9 2017: 1136-1140 es
dc.identifier.uri http://hdl.handle.net/10550/63374
dc.description.abstract This study compared the incidence of deviation along curved canals after preparation with two nickel-titanium (NiTi) rotary systems, Twisted File Adaptive and BT-RaCe. Forty resin training blocks with curved canals were filled with ink and divided into two groups according to the instrumentation technique. Preinstrumentation images were acquired by using a stereomicroscope. The canals were up to an instrument #35/0.04. Postinstrumentation images were captured using the same conditions, and the images were superimposed. The amount of resin removed was measured at 8 different points, beginning at the apical terminus of the canal. Differences in the mesial and distal aspects were measured to evaluate the occurrence of deviation. The Student?s-t test was used for comparison of the intragroup deviation. Intergroup analysis was performed by using one-way ANOVA for each level. For multiple comparisons, the Bonferroni test was used and a cutoff for significance was set at 5%. Intragroup analysis showed that both instrumentation techniques promoted some deviation at all levels. BT-RaCe showed significantly lower deviation at 0 and 4-mm levels than Group Twisted File Adaptive (p<0.05). On the other hand BT-RaCe showed worse performance at level 6. The results of this study demonstrated that none of the NiTi tested systems was able to instrument curved canals simulated in resin blocks without some deviation during the preparation. There is still need for improvement in the instruments manufacturing aiming the better performance of endodontic files in curved root canals. es
dc.title Transportation assessment in simulated curved canals after preparation with twisted file adaptive and bt-race instruments es
dc.type journal article es_ES
dc.subject.unesco UNESCO::CIENCIAS MÉDICAS es
dc.identifier.doi 10.4317/jced.54220 es
dc.type.hasVersion VoR es_ES

Visualització       (759.1Kb)

Aquest element apareix en la col·lecció o col·leccions següent(s)