NAGIOS: RODERIC FUNCIONANDO

Preload loss of abutment screws after dynamic fatigue in single implant-supported restorations. A systematic review

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Preload loss of abutment screws after dynamic fatigue in single implant-supported restorations. A systematic review

Mostra el registre parcial de l'element

dc.contributor.author Pardal Peláez, Beatriz es
dc.contributor.author Montero Martín, Javier es
dc.date.accessioned 2018-02-28T11:26:55Z
dc.date.available 2018-02-28T11:26:55Z
dc.date.issued 2017 es
dc.identifier.citation Pardal Peláez, Beatriz ; Montero Martín, Javier. Preload loss of abutment screws after dynamic fatigue in single implant-supported restorations. A systematic review. En: Journal of Clinical and Experimental Dentistry, 9 11 2017: 1355-1361 es
dc.identifier.uri http://hdl.handle.net/10550/65076
dc.description.abstract To carry out a systematic literature review of the causes of preload loss of the abutment screws, of internal and external connection implants, tightened to different torque values and subjected to cyclic loading. A systematic search was conducted in PubMed, EMBASE, and Cochrane Library databases with reference to in vitro studies in which internal and external connection implants were subjected to cyclic loads to determine the degree of loosening of the abutment screws after loading. The reviewed studies tested distinct implant connections (mostly externally hexed, and morse taper) subjected to diverse cycles (from 16667 to 1 million), with loads ranging from 0-400 Nw, using screws of different materials and designs that were tightened into torques between 20-45 Ncm, Accordingly after loading the percentage of torque loss ranges between 16.1% to 39%. Most of the studies indicate that the internal connection, together with the morse taper, best resists cyclic loading in terms of screw loosening in single-tooth implants. es
dc.title Preload loss of abutment screws after dynamic fatigue in single implant-supported restorations. A systematic review es
dc.type journal article es_ES
dc.subject.unesco UNESCO::CIENCIAS MÉDICAS es
dc.identifier.doi 10.4317/jced.54374 es
dc.type.hasVersion VoR es_ES

Visualització       (617.8Kb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques