NAGIOS: RODERIC FUNCIONANDO

High Sensitivity Refractive Index Sensor Based on Highly Overcoupled Tapered Fiber Optic Couplers

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

High Sensitivity Refractive Index Sensor Based on Highly Overcoupled Tapered Fiber Optic Couplers

Mostra el registre parcial de l'element

dc.contributor.author Hernández-Arriaga, M. V.
dc.contributor.author Bello-Jiménez, M.
dc.contributor.author Rodríguez-Cobos, A.
dc.contributor.author López-Estopier, R.
dc.contributor.author Andrés, Miguel V.
dc.date.accessioned 2018-04-10T11:35:05Z
dc.date.available 2018-04-10T11:35:05Z
dc.date.issued 2017 es_ES
dc.identifier.citation M. V. Hernández-Arriaga, M. Bello-Jiménez, A. Rodríguez-Cobos, R. López-Estopier y M. V. Andrés, "High Sensitivity Refractive Index Sensor Based on Highly Overcoupled Tapered Fiber Optic Couplers", IEEE Sensors Journal, Vol. 17, pp. 333-339, 2017 es_ES
dc.identifier.uri http://hdl.handle.net/10550/65544
dc.description.abstract In this paper, a simple and compact fiber-optic sensor based on an overcoupled tapered fiber coupler is studied. The coupler is fabricated to be operated well beyond the initial coupling cycles, where the rapid exchange of energy between outputs ports enable the fabrication of a highly sensitive device. The suitability and sensitivity of the proposed scheme is demonstrated by measuring refractive index (RI) variations of sugar concentrations in water. The device presents a linear response in terms of power transmission or wavelength shift versus RI changes. The best achieved sensitivity is 0.442 units of normalized transmission per unit of sugar concentration, with a noise detection limit of 0.003 weight percentage of sugar concentration (wt %). From this result the minimum detectable RI change is estimated as 5 × 10-6 RI unit (RIU). The sensor can be also wavelength-encoded, exhibiting a sensitivity of 2171 nm/RIU, maintaining a linear response in a large range of RI. These experimental results are within the best results reported in the framework of fiber couplers and modal interferometer-based RI sensors es_ES
dc.language.iso en es_ES
dc.subject Couplers es_ES
dc.subject Optical fiber sensors es_ES
dc.subject Optical fiber couplers es_ES
dc.subject Couplings es_ES
dc.title High Sensitivity Refractive Index Sensor Based on Highly Overcoupled Tapered Fiber Optic Couplers es_ES
dc.type journal article es_ES
dc.subject.unesco UNESCO::FÍSICA::Óptica ::Fibras ópticas es_ES
dc.identifier.doi 10.1109/JSEN.2016.2629281 es_ES
dc.type.hasVersion AM es_ES

Visualització       (463.1Kb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques