NAGIOS: RODERIC FUNCIONANDO

Evaluation of micro shear bonding strength of two universal dentin bondings to superficial dentin by self etch and etch-and-rinse strategies

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Evaluation of micro shear bonding strength of two universal dentin bondings to superficial dentin by self etch and etch-and-rinse strategies

Mostra el registre parcial de l'element

dc.contributor.author Daneshkazemi, Pedram es
dc.contributor.author Ghasemi, Amir es
dc.contributor.author Daneshkazemi, Alireza es
dc.contributor.author Shafiee, Fahime es
dc.date.accessioned 2018-11-28T12:48:33Z
dc.date.available 2018-11-28T12:48:33Z
dc.date.issued 2018 es
dc.identifier.citation Daneshkazemi, Pedram ; Ghasemi, Amir ; Daneshkazemi, Alireza ; Shafiee, Fahime. Evaluation of micro shear bonding strength of two universal dentin bondings to superficial dentin by self etch and etch-and-rinse strategies. En: Journal of Clinical and Experimental Dentistry, 10 9 2018: 837-843 es
dc.identifier.uri http://hdl.handle.net/10550/68130
dc.description.abstract Universal bondings can be used either with the etch-and-rinse or self-etch technique. Thus, the present study was done to evaluate the micro-shear bonding strength of two types of Universal Bondings to superficial dentin i.e self-etch and etch and rinse. The samples included 70 tooth blocks taken from 35 extracted sound premolar teeth. The superficial dentin was exposed to grinding by 800 grit silicon carbide Disk. The samples were randomly divided into 5 equal groups (14 samples in each group). Scotch bond universal (3M/USA) and All bond universal (BISCO/USA) were applied by self-etch and etch and rinse technique in group 1-4 and Adper Single bond 2 (3M/USA) was used in group 5 as etch and rinse for the control group. Z250 XT (3M/USA) resin composite was bonded in tygon tube on surfaces of samples and were cured. Specimens were stored in distilled water at 37ºC for 24 h and then subjected to the micro shear bond strength test in a universal testing machine at a crosshead speed of 0.5 mm/min. The data were analyzed by two-way ANOVA and Tukey test. Failure mode was determined using a stereomicroscope under 20X magnification. Significance level was considered 0/05. The mean of micro-shear bonding strength and Standard Deviation of groups in Mega Pascal are respectively: 35.74 (6.21), 29.50 (3.89), 24.60 (3.53), 31.47 (4.73), 18.09 (3.87). The self-etch technique for Scotch bond Universal and the etch and rinse technique for All bond Universal showed higher micro shear bonding strength. Adper single bond 2 showed the lowest bond strength to a significant level in comparison to other groups (p<0.05). Failure mode was predominantly adhesive. The micro shear bonding strength of universal adhesives was highly bonding-dependent. Universal bondings had higher micro-shear bonding strength than Adper single bond 2. es
dc.title Evaluation of micro shear bonding strength of two universal dentin bondings to superficial dentin by self etch and etch-and-rinse strategies es
dc.type journal article es_ES
dc.subject.unesco UNESCO::CIENCIAS MÉDICAS es
dc.identifier.doi 10.4317/jced.54740 es
dc.type.hasVersion VoR es_ES

Visualització       (401.9Kb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques