NAGIOS: RODERIC FUNCIONANDO

Micro-computed tomographic evaluation of dentinal defects after root canal preparation with hyflex edm and vortex blue rotary systems

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Micro-computed tomographic evaluation of dentinal defects after root canal preparation with hyflex edm and vortex blue rotary systems

Mostra el registre parcial de l'element

dc.contributor.author Mandava, Jyothi es
dc.contributor.author Yelisela, Rajiv-Kumar es
dc.contributor.author Arikatla, Sampath-Kumar es
dc.contributor.author Ravi, Ravichandra es
dc.date.accessioned 2018-11-28T12:48:35Z
dc.date.available 2018-11-28T12:48:35Z
dc.date.issued 2018 es
dc.identifier.citation Mandava, Jyothi ; Yelisela, Rajiv-Kumar ; Arikatla, Sampath-Kumar ; Ravi, Ravichandra. Micro-computed tomographic evaluation of dentinal defects after root canal preparation with hyflex edm and vortex blue rotary systems. En: Journal of Clinical and Experimental Dentistry, 10 9 2018: 844-851 es
dc.identifier.uri http://hdl.handle.net/10550/68131
dc.description.abstract To evaluate the incidence of dentinal microcracks formation after root canal shaping procedures with HyFlex EDM and Vortex Blue rotary systems comparing with that of hand instrumentation using micro-computed tomography. Mandibular first molar teeth (n=60) having 50 to 200mesial root curvature were scanned using high resolution micro-CT imaging before root canal preparation to identify the presence of dentinal defects. Post-instrumentation cross-sectional images were taken and increased number and type of root defects were assessed and recorded. The data was statistically analysed by using chi-square test and McNemar?s test at a significance level of 5%. HyFlex EDM has shown greater increase in post instrumentation dentinal defects. Both rotary systems exhibited increased dentinal defects formation at coronal, middle regions which is statistically significant (P=0.042) when compared to apical region. HyFlex EDM has shown greater increase in post instrumentation dentinal defects followed by Vortex Blue rotary system and hand instrumentation resulted minimal defects. es
dc.title Micro-computed tomographic evaluation of dentinal defects after root canal preparation with hyflex edm and vortex blue rotary systems es
dc.type journal article es_ES
dc.subject.unesco UNESCO::CIENCIAS MÉDICAS es
dc.identifier.doi 10.4317/jced.54853 es
dc.type.hasVersion VoR es_ES

Visualització       (1.412Mb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques