NAGIOS: RODERIC FUNCIONANDO

Implant insertion torque value in immediate loading : a retrospective study

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Implant insertion torque value in immediate loading : a retrospective study

Mostra el registre parcial de l'element

dc.contributor.author Del Giudice, Roberto es
dc.contributor.author Piattelli, Adriano es
dc.contributor.author Grande, Nicola es
dc.contributor.author Cataneo, Enrico es
dc.contributor.author Crispino, Antonio es
dc.contributor.author Petrini, Morena es
dc.date.accessioned 2019-07-02T09:55:56Z
dc.date.available 2019-07-02T09:55:56Z
dc.date.issued 2019 es
dc.identifier.citation Del Giudice, Roberto ; Piattelli, Adriano ; Grande, Nicola ; Cataneo, Enrico ; Crispino, Antonio ; Petrini, Morena. Implant insertion torque value in immediate loading : a retrospective study. En: Medicina oral, patología oral y cirugía bucal. Ed. inglesa, 24 3 2019: 1- es
dc.identifier.uri https://hdl.handle.net/10550/70665
dc.description.abstract The aim of this study is to verify if the Insertion Torque Value (ITV) of 32 Ncm for immediate loading protocol (ILP), as indicated by literature, is still, with the advance in implant research, a real significant cut-off for long-term implant survival. In this retrospective study, data from 224 patients that during three years of clinical practice, were submitted to the insertion of 322 implants with immediate loading protocol, have been recorded, pooled and analyzed. Data were organized based on Insertion Torque Value (ITV): > 32 Ncm (CG) and < 32 Ncm (LTG) and two different groups of equal sample size, 161 implants each, were distinguished. Crestal bone reabsorption, and the implant failure rate were evaluated after 2-years of follow-up. The bone reabsorption in LTG (0.49 ± 0.11 mm) was significantly greater than CG (0.22 ± 0.04 mm), p<0.001. However, the survival rate after 2-years of follow-up was quite high and similar for both groups: 96.89% for LTG and 97.52% for CG and no statistically significant differences have been found among the two groups for the implant failure rate (p=0.455). The Odds Ratio (OR) of implant failure was of 1.258 (95% CI 0.332, 4.772), but results were not statistical significant, p=0.740. The present study showed that although implants with ITV> 32 Ncm are still characterized by a lower crestal bone resorption, there are no statistically significant differences among the two groups for what concerning the failure rate during the 2 years of follow-up and OR. These results permit us to suppose that the cut-off of ITV >32 Ncm for immediate loading implants, could be reduced to inferior values. However further studies are necessary to indicate precise clinical guidelines. es
dc.title Implant insertion torque value in immediate loading : a retrospective study es
dc.type journal article es_ES
dc.subject.unesco UNESCO::CIENCIAS MÉDICAS es
dc.identifier.doi 10.4317/medoral.22845 es
dc.type.hasVersion VoR es_ES

Visualització       (595.5Kb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques