Mostra el registre parcial de l'element
dc.contributor.author | Lafosse, Edouard | |
dc.contributor.author | Martínez Albert, Noelia | |
dc.contributor.author | Wolffsohn, James | |
dc.contributor.author | Cerviño Expósito, Alejandro | |
dc.contributor.author | García Lázaro, Santiago | |
dc.date.accessioned | 2019-09-16T13:19:31Z | |
dc.date.available | 2020-01-01T05:45:04Z | |
dc.date.issued | 2019 | |
dc.identifier.citation | Lafosse, Edouard Martínez Albert, Noelia Wolffsohn, James Cerviño Expósito, Alejandro García Lázaro, Santiago 2019 Response of the Aging Eye to First Day of Modern Material Contact Lens Wear Eye & Contact Lens-Science And Clinical Practice 45 1 40 45 | |
dc.identifier.uri | https://hdl.handle.net/10550/71536 | |
dc.description.abstract | Objectives: To investigate the ocular surface of an aged population wearing a daily disposable contact lens over their first day of wear. Methods: Forty eyes from forty presbyopic subjects were fitted a daily CL (Delefilcon A). Tear osmolarity, tear meniscus area (TMA) and ocular surface aberrations (total higher order root means square (RMS)) were assessed at baseline (t0), at 20 minutes (t1) and after 8 hours (t2) of wear. Fluorescein corneal and conjunctival staining and tear break up time (TBUT) were performed at t0 and t2. Results: No statistically significant changes were found between t0, t1 and t2 for TMA, and between t0 and t2 for fluorescein corneal and conjunctival staining. TBUT worsened by the end of the day from 10.4±0.4 seconds t0 to 9.0±0.3 seconds t2 (P <0.05). Osmolarity showed significant changes between t0 306.9±2.3 mOsm/L and t1 312.4±2.4 mOsmol/L (P = 0.02), but returned to baseline values at 8 hours (310.40±2.26 mOsm/L; P = 0.09). Total higher order root means square (RMS) showed significant changes between t0 0.38±0.02 μm and t1 0.61±0.04 μm (P ≤ 0.001) and between t0 and t2 0.64±0.41 μm (P ≤ 0.001). Conclusions: Delefilcon A may induce measures changes (osmolarity and TBUT values) in a presbyopic population, however TMA and vital staining were maintained at the baseline level over the day. | |
dc.language.iso | eng | |
dc.relation.ispartof | Eye & Contact Lens-Science And Clinical Practice, 2019, vol. 45, num. 1, p. 40-45 | |
dc.subject | Òptica Aparells i instruments | |
dc.subject | Ulls Acomodació i refracció | |
dc.title | Response of the aging eye to first day of modern material contact lens wear | |
dc.type | journal article | es_ES |
dc.date.updated | 2019-09-16T13:19:31Z | |
dc.identifier.doi | 10.1097/ICL.0000000000000514 | |
dc.identifier.idgrec | 131456 | |
dc.embargo.terms | 1 year | |
dc.rights.accessRights | open access | es_ES |