NAGIOS: RODERIC FUNCIONANDO

A statistical design of experiments for optimizing the MALDI-TOF-MS sample preparation of polymers. An application in the assessment of the thermo-mechanical degradation mechanisms of poly (ethylene terephthalate)

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

A statistical design of experiments for optimizing the MALDI-TOF-MS sample preparation of polymers. An application in the assessment of the thermo-mechanical degradation mechanisms of poly (ethylene terephthalate)

Mostra el registre parcial de l'element

dc.contributor.author Badia Valiente, José David
dc.contributor.author Strömberg, E.
dc.contributor.author Ribes Greus, A.
dc.contributor.author Karlsson, S.
dc.date.accessioned 2019-10-28T18:25:18Z
dc.date.available 2019-10-28T18:25:18Z
dc.date.issued 2011
dc.identifier.citation Badia Valiente, José David Strömberg, E. Ribes Greus, A. Karlsson, S. 2011 A statistical design of experiments for optimizing the MALDI-TOF-MS sample preparation of polymers. An application in the assessment of the thermo-mechanical degradation mechanisms of poly (ethylene terephthalate) Analytica Chimica Acta 692 1-2 85 95
dc.identifier.uri https://hdl.handle.net/10550/71821
dc.description.abstract The sample preparation procedure for MALDI-TOF MS of polymers is addressed in this study by the application of a statistical Design of Experiments (DoE). Industrial poly (ethylene terephthalate) (PET) was chosen as model polymer. Different experimental settings (levels) for matrixes, analyte/matrix proportions and concentrations of cationization agent were considered. The quality parameters used for the analysis were signal-to-noise ratio and resolution. A closer inspection of the statistical results provided the study not only with the best combination of factors for the MALDI sample preparation, but also with a better understanding of the influence of the different factors, individually or in combination, to the signal. The application of DoE for the improvement of the MALDI measure of PET stated that the best combination of factors and levels was the following: matrix (dithranol), proportion analyte/matrix/cationization agent (1/15/1, V/V/V), and concentration of cationization agent (2 g L−1). In a second part, multiple processing by means of successive injection cycles was used to simulate the thermo-mechanical degradation effects on the oligomeric distribution of PET under mechanical recycling. The application of MALDI-TOF-MS showed that thermo-mechanical degradation primarily affected initially predominant cyclic species. Several degradation mechanisms were proposed, remarking intramolecular transesterification and hydrolysis. The ether links of the glycol unit in PET were shown to act as potential reaction sites, driving the main reactions of degradation.
dc.language.iso eng
dc.relation.ispartof Analytica Chimica Acta, 2011, vol. 692, num. 1-2, p. 85-95
dc.subject Termoplàstics
dc.subject Solucions polimèriques
dc.title A statistical design of experiments for optimizing the MALDI-TOF-MS sample preparation of polymers. An application in the assessment of the thermo-mechanical degradation mechanisms of poly (ethylene terephthalate)
dc.type journal article es_ES
dc.date.updated 2019-10-28T18:25:18Z
dc.identifier.doi 10.1016/j.aca.2011.02.063
dc.identifier.idgrec 134911
dc.rights.accessRights open access es_ES

Visualització       (663.7Kb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element