NAGIOS: RODERIC FUNCIONANDO

Improving detection limits for organotin compounds in several matrix water samples by derivatization-headspace-solid-phase microextraction and GC-MS

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Improving detection limits for organotin compounds in several matrix water samples by derivatization-headspace-solid-phase microextraction and GC-MS

Mostra el registre parcial de l'element

dc.contributor.author Segovia Martinez, Laura
dc.contributor.author Bouzas Blanco, Alberto
dc.contributor.author Campíns Falcó, Pilar
dc.contributor.author Seco Torrecillas, Aurora
dc.date.accessioned 2019-11-11T15:02:52Z
dc.date.available 2019-11-11T15:02:52Z
dc.date.issued 2010
dc.identifier.citation Segovia Martinez, Laura Bouzas Blanco, Alberto Campíns Falcó, Pilar Seco Torrecillas, Aurora 2010 Improving detection limits for organotin compounds in several matrix water samples by derivatization-headspace-solid-phase microextraction and GC-MS Talanta 80 5 1888 1893
dc.identifier.uri https://hdl.handle.net/10550/72166
dc.description.abstract Triethyltin, tributyltin, diphenyltin and triphenyltin were selected as model compounds. The method is based on in situ ethylation and simultaneous headspace-solid-phase microextraction (HS-SPME) and gas chromatographic-mass spectrometry analysis (GC-MS). The extraction procedure was optimized studying some variables such as reaction time, salinity, sample volume and headspace volume. SPME-GC-MS and SPME-GC-FID techniques were compared; quality assurance parameters such as sensitivity, selectivity and precision were established. The proposed procedure showed limits of detection between 0.025 and 1 ng/L. The linearity was in the 0.025-5000 ng/L range. The precision expressed as relative standard deviations (RSD), were below 20%. Real wastewaters and seawaters were analyzed. The method permits controlling legislated annual average values.
dc.language.iso eng
dc.relation.ispartof Talanta, 2010, vol. 80, num. 5, p. 1888-1893
dc.subject Compostos organometàl·lics
dc.subject Cromatografia de gasos
dc.subject Aigües residuals Anàlisi
dc.title Improving detection limits for organotin compounds in several matrix water samples by derivatization-headspace-solid-phase microextraction and GC-MS
dc.type journal article es_ES
dc.date.updated 2019-11-11T15:02:52Z
dc.identifier.doi 10.1016/j.talanta.2009.10.039
dc.identifier.idgrec 054494
dc.rights.accessRights open access es_ES

Visualització       (188.0Kb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques