dc.contributor.author Satyanarayana, Tammineedi S.V. es
dc.contributor.author Rai, Rathika es
dc.contributor.author Subramanyam, E. es
dc.contributor.author Illango, T. es
dc.contributor.author Mutyala, Vishwabharathi es
dc.contributor.author Akula, Rajesh es
dc.date.accessioned 2019-11-22T12:20:51Z
dc.date.available 2019-11-22T12:20:51Z
dc.date.issued 2019 es
dc.identifier.citation Satyanarayana, Tammineedi S.V. ; Rai, Rathika ; Subramanyam, E. ; Illango, T. ; Mutyala, Vishwabharathi ; Akula, Rajesh. Finite element analysis of stress concentration between surface coated implants and non surface coated implants - An in vitro study. En: Journal of Clinical and Experimental Dentistry, 11 8 2019: 713-720 es
dc.identifier.uri https://hdl.handle.net/10550/72300
dc.description.abstract To determine qualitative comparison in stress distribution between surface coated implants and non surface coated implants using 2 different lengths and vertical, oblique, and lateral forces. 3 dimensional finite element study was carried out at first molar site with 4 surface coated and 4 non surface coated implants using mimic 8.11, solid edge 2004, hypermesh 9.0, and ansys12.1 software. The pattern of stress distribution was almost similar between vertical and oblique loading but varied with lateral loads between surface coated and non surface coated implants. As the length of the implants increased stress concentration had no significant variation between surface coated and non surface coated implants, but had a tendency to increase at the abutment and abutment screw on all 3 forces. Among the surface coated and non surface implants the pattern of stress distribution was similar signifying that surface coating of implants had no significant role in stress distribution using 3d finite element analysis and within the limitations of this study. es
dc.title Finite element analysis of stress concentration between surface coated implants and non surface coated implants - An in vitro study es
dc.type journal article es_ES
dc.subject.unesco UNESCO::CIENCIAS MÉDICAS es
dc.identifier.doi 10.4317/jced.55915 es