NAGIOS: RODERIC FUNCIONANDO

Clinical effect of diode laser on peri-implant tissues during non-surgical peri-implant mucositis therapy : randomized controlled clinical study

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Clinical effect of diode laser on peri-implant tissues during non-surgical peri-implant mucositis therapy : randomized controlled clinical study

Mostra el registre parcial de l'element

dc.contributor.author Sánchez-Martos, Rebeca es
dc.contributor.author Samman, Andrea es
dc.contributor.author Bouazza Juanes, Kheira es
dc.contributor.author Díaz Fernández, José María es
dc.contributor.author Arias Herrera, Santiago Emilio es
dc.date.accessioned 2020-10-21T09:18:27Z
dc.date.available 2020-10-21T09:18:27Z
dc.date.issued 2020 es
dc.identifier.citation Sánchez-Martos, Rebeca ; Samman, Andrea ; Bouazza Juanes, Kheira ; Díaz Fernández, José María ; Arias Herrera, Santiago Emilio. Clinical effect of diode laser on peri-implant tissues during non-surgical peri-implant mucositis therapy : randomized controlled clinical study. En: Journal of Clinical and Experimental Dentistry, 12 1 2020: 13-21 es
dc.identifier.uri https://hdl.handle.net/10550/75974
dc.description.abstract The aim of this study is to evaluate the response to the non-surgical treatment of peri-implant mucositis using the diode laser as an adjuvant therapy in patients with implant-supported restorations, in terms of clinical variables, with respect to those patients in whom conventional non-surgical therapy is used. Randomized controlled clinical trial with simple blind 3 months follow-up. Two groups of patients were established, the non-surgical mechanical debridement of the affected implants was performed in the control group (n = 34) and the diode laser therapy was also performed in the test group (n = 34). The implant was considered the study subject; the variables considered were plaque index, bleeding on probing depth, depth of probing and recession of the peri-implant mucosa. The t-Student test was used to establish the intergroup statistical differences and the analysis of variance (ANOVA) was used to measures intragroup differences over time. In the revaluation at 6 weeks, we observed statistically significant differences (p<0.05) between the variables of plaque index and depth of probing between both groups. The test group obtained an average of 0.248 ± 0.3155 in plaque index and 0.833 ± 0.374mm in the depth of probing compared to the results obtained in the control group that was 0.558 ± 0.526 and 1,137 ± 0.222mm respectively. In the 3-month reevaluation, was also obtained great statistical significance between both groups for bleeding on probing (p<0.001), with values of 0.568 ± 0.282 for the control group and 0.480 ± 0.336 for the test group. The use of diode laser as an adjunctive therapy to the conventional treatment of peri-implant mucositis showed promising results, being more effective reducing the inflammation of the peri-implant tissue, positioning itself as a valuable tool for the treatment of peri-implant pathologies. es
dc.title Clinical effect of diode laser on peri-implant tissues during non-surgical peri-implant mucositis therapy : randomized controlled clinical study es
dc.type journal article es_ES
dc.subject.unesco UNESCO::CIENCIAS MÉDICAS es
dc.identifier.doi 10.4317/medoral.56424 es
dc.type.hasVersion VoR es_ES

Visualització       (1.477Mb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques