NAGIOS: RODERIC FUNCIONANDO

Architectural Ultrasound Pennation Angle Measurement of Lumbar Multifidus Muscles: A Reliability Study

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Architectural Ultrasound Pennation Angle Measurement of Lumbar Multifidus Muscles: A Reliability Study

Mostra el registre parcial de l'element

dc.contributor.author Monsalve-Vicente, Cristina
dc.contributor.author Muñoz-Zamarro, Daniel
dc.contributor.author Cuenca-Zaldívar, Nicolás
dc.contributor.author Fernández-Carnero, Samuel
dc.contributor.author Selva, Francisco
dc.contributor.author Nunez-Nagy, Susana
dc.contributor.author Naranjo-Cinto, Fermin
dc.contributor.author Gallego-Izquierdo, Tomás
dc.date.accessioned 2022-12-12T07:45:21Z
dc.date.available 2022-12-12T07:45:21Z
dc.date.issued 2022
dc.identifier.citation Monsalve-Vicente, Cristina Muñoz-Zamarro, Daniel Cuenca-Zaldívar, Nicolás Fernández-Carnero, Samuel Selva, Francisco Nunez-Nagy, Susana Naranjo-Cinto, Fermin Gallego-Izquierdo, Tomás 2022 Architectural Ultrasound Pennation Angle Measurement of Lumbar Multifidus Muscles: A Reliability Study Journal Of Clinical Medicine 11 5174
dc.identifier.uri https://hdl.handle.net/10550/84709
dc.description.abstract The pennation angle has been shown to be a relevant parameter of muscle architecture. This parameter has not previously been measured in the lumbar multifidus musculature, and it is for this reason that it has been considered of great interest to establish an assessment protocol to generate new lines of research in the future. Objective: The objective of this study was to establish a protocol for measuring the pennation angle of the multifidus muscles, with a study of intra-rater and interrater reliability values. Design: This was a reliability study following the recommendations of the Guidelines for Reporting Reliability and Agreement Studies (GRRAS). Setting: The study was carried out at University of Alcalá, Department of Physiotherapy. Subjects: Twenty-seven subjects aged between 18 and 55 years were recruited for this study. Methods: Different ultrasound images of the lumbar multifidus musculature were captured. Subsequently, with the help of ImageJ software, the pennation angle of this musculature was measured. Finally, a complex statistical analysis determined the intra- and interrater reliability. Results: The intra-rater reliability of the pennation angle measurement protocol was excellent for observer 1 in the measurement of the left-sided superficial multifidus 0.851 (0.74, 0.923), and for observer 2 in the measurement of the right-sided superficial 0.711 (0.535, 0.843) and deep multifidus 0.886 (0.798, 0.942). Interrater reliability was moderate to poor, and correlation analysis results were high for thickness vs. pennation angle. Conclusions: The designed protocol for ultrasound measurement of the pennation angle of the lumbar multifidus musculature has excellent intra-rater reliability values, supporting the main conclusions and interpretations. Normative ranges of pennation angles are reported. High correlation between variables is described.
dc.language.iso eng
dc.relation.ispartof Journal Of Clinical Medicine, 2022, vol. 11, p. 5174
dc.subject Fisioteràpia
dc.title Architectural Ultrasound Pennation Angle Measurement of Lumbar Multifidus Muscles: A Reliability Study
dc.type journal article es_ES
dc.date.updated 2022-12-12T07:45:22Z
dc.identifier.idgrec 155866
dc.rights.accessRights open access es_ES

Visualització       (1.727Mb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques