NAGIOS: RODERIC FUNCIONANDO

Nucleus disc replacement : designs and material selection FEA analysis

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Nucleus disc replacement : designs and material selection FEA analysis

Mostra el registre parcial de l'element

dc.contributor.author Vanaclocha-Saiz, Amparo
dc.contributor.author Vanaclocha Vanaclocha, Vicente
dc.contributor.author Atienza Vicente, Carlos M.
dc.contributor.author Clavel, Pablo
dc.contributor.author Jordá Gómez, P.
dc.contributor.author Barrios, Carlos
dc.contributor.author Sáiz-Sapena, Nieves
dc.contributor.author Vanaclocha, Leyre
dc.date.accessioned 2023-03-23T15:42:27Z
dc.date.available 2023-03-23T15:42:27Z
dc.date.issued 2022
dc.identifier.citation Vanaclocha-Saiz, Amparo Vanaclocha Vanaclocha, Vicente Atienza Vicente, Carlos M. Clavel, Pablo Jordá Gómez, P. Barrios, Carlos Sáiz-Sapena, Nieves Vanaclocha, Leyre 2022 Nucleus disc replacement : designs and material selection FEA analysis Advances In Materials Science And Engineering
dc.identifier.uri https://hdl.handle.net/10550/85894
dc.description.abstract Study design. Material selection, implant design and Finite Element Analysis (FEA) studies. Background. Nucleus disc replacements, implanted since 1960, have undergone continuous evolution in materials and designs, but subsidence, extrusion, and in vivo degradation limit widespread use. Aim: To create a new nucleus disc replacement that avoids the abovementioned drawbacks. Material and Methods. We created eighteen designs with varied materials and analyzed them with FEA in compression and shear tests in a lumbar spine model programmed in Ansys Parametric Design Language. Results. Bionate® 80A had the closest mechanical characteristics to the intact disc nucleus. Monobloc designs bore the physiological stresses correctly but suffered significant deformations with permanent damage during surgical insertion through the annulus opening. In addition, sandwich designs were too rigid and had an unreliable curing process. Therefore, we chose an oval doughnut-like 5 mm wall monobloc Bionate® 80A nucleus replacement. It minimized implant stress in loading, distributed the loads uniformly, and tolerated the lateral compression during implantation. Conclusions. Out of the eighteen designs we analyzed with FEA, we found that the monobloc oval doughnut-like Bionate 80A nucleus replacement reproduced best the biomechanics of the natural disc nucleus and had the lowest subsidence risk as it transmits the load to the ring apophysis. Furthermore, due to its elasticity implanting it through the average annulotomy required to perform a lumbar microdiscectomy should be possible.
dc.relation.ispartof Advances In Materials Science And Engineering, 2022
dc.subject Medicina Investigació
dc.title Nucleus disc replacement : designs and material selection FEA analysis
dc.type journal article es_ES
dc.date.updated 2023-03-23T15:42:27Z
dc.identifier.doi 10.1155/2022/5040747
dc.identifier.idgrec 156888
dc.rights.accessRights open access es_ES