NAGIOS: RODERIC FUNCIONANDO

Validations of Blood Pressure Measuring Devices Using Recognized Protocols

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Validations of Blood Pressure Measuring Devices Using Recognized Protocols

Mostra el registre parcial de l'element

dc.contributor.author Mazoteras Pardo, Victoria
dc.contributor.author Gómez Cantarino, Sagrario
dc.contributor.author Ramírez Jiménez, Miguel
dc.contributor.author Navarro Flores, Emmanuel
dc.contributor.author Ugarte Gurrutxaga, María Idoia
dc.date.accessioned 2023-05-02T14:47:00Z
dc.date.available 2023-05-02T14:47:00Z
dc.date.issued 2022
dc.identifier.citation Mazoteras Pardo, Victoria Gómez Cantarino, Sagrario Ramírez Jiménez, Miguel Navarro Flores, Emmanuel Ugarte Gurrutxaga, María Idoia 2022 Validations of Blood Pressure Measuring Devices Using Recognized Protocols Journal Of Personalized Medicine 13(1) 9 1 18
dc.identifier.uri https://hdl.handle.net/10550/86277
dc.description.abstract Preventing, diagnosing, and controlling high blood pressure is a global health priority. The self-measurement of blood pressure is therefore fundamental and should be done with devices validated by recognized protocols, although most are not. The most widely used and current protocols are the 2010 European Society of Hypertension (ESH) revision and the 2018 Association for the Advancement of Medical Instrumentation (AAMI)/ ESH/ the International Organization for Standardization (ISO) universal standard, respectively. The aim of this study was to find out which blood pressure measuring devices have been adequately validated by the above protocols. A narrative review of blood pressure device validations was conducted by searching the PubMed database. From 52 records identified, 37 studies were included. Most validations follow the 2010 revision and only six follow the 2018 protocol, which is more demanding. Almost all validated sphygmomanometers are automated oscillometric sphygmomanometers in the general population. Wrist devices and devices combining new technologies are also validated, as well as in specific populations, such as the obese, pregnant women, or children. There is sufficient evidence to confirm that the universal AAMI/ ESH/ISO standard is considered the protocol of the century. However, it is necessary to increase the number of validations following it and, above all, validations of the new technologies that are invading the current market.
dc.language.iso spa
dc.relation.ispartof Journal Of Personalized Medicine, 2022, vol. 13(1), num. 9, p. 1-18
dc.subject Pressió sanguínia
dc.subject Salut pública
dc.title Validations of Blood Pressure Measuring Devices Using Recognized Protocols
dc.type journal article
dc.date.updated 2023-05-02T14:47:00Z
dc.identifier.doi 10.3390/jpm13010009
dc.identifier.idgrec 158049
dc.rights.accessRights open access

Visualització       (818.5Kb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques