NAGIOS: RODERIC FUNCIONANDO

Comparison of validation protocols for blood pressure measuring devices in children and adolescents

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Comparison of validation protocols for blood pressure measuring devices in children and adolescents

Mostra el registre parcial de l'element

dc.contributor.author Stabouli, Stella
dc.contributor.author Chainoglou, Athanasia
dc.contributor.author Evripidou, Kleo
dc.contributor.author Simao, Carla
dc.contributor.author Antza, Christina
dc.contributor.author Petrou, Panagiotis
dc.contributor.author Hamdani, Gilad
dc.contributor.author Calpe Maravilla, Javier
dc.contributor.author Lurbe i Ferrer, Empar
dc.date.accessioned 2023-05-02T17:34:45Z
dc.date.available 2023-05-02T17:34:45Z
dc.date.issued 2022
dc.identifier.citation Stabouli, Stella Chainoglou, Athanasia Evripidou, Kleo Simao, Carla Antza, Christina Petrou, Panagiotis Hamdani, Gilad Calpe Maravilla, Javier Lurbe i Ferrer, Empar 2022 Comparison of validation protocols for blood pressure measuring devices in children and adolescents Frontiers In Cardiovascular Medicine 9 1001878 1001878
dc.identifier.uri https://hdl.handle.net/10550/86286
dc.description.abstract Accuracy of blood pressure (BP) measurement is important for the evaluation of hypertension in children and adolescents, and it is critically dependent upon the accuracy of the BP measuring device. A device that could pass validated protocols with reliable accuracy would be desirable in clinical and research settings. Several scientific organizations have published recommendations on the validation of different BP measuring devices. Most of them focus on adults but separate recommendations and validation criteria for BP devices intended for use in children and adolescents are included in some validation protocols. In this review, we compare the validation criteria for BP measuring devices among consensus documents from different scientific organizations focusing on the pediatric population and we discuss the evidence gaps targeting the needs for validated BP measuring devices in children and adolescents. We also highlight common pitfalls in the validation studies of BP measuring devices in children and adolescents using the example of office BP devices.
dc.language.iso eng
dc.relation.ispartof Frontiers In Cardiovascular Medicine, 2022, num. 9, p. 1001878-1001878
dc.subject Pressió sanguínia
dc.subject Infants
dc.subject Joves
dc.title Comparison of validation protocols for blood pressure measuring devices in children and adolescents
dc.type journal article
dc.date.updated 2023-05-02T17:34:45Z
dc.identifier.doi 10.3389/fcvm.2022.1001878
dc.identifier.idgrec 157964
dc.rights.accessRights open access

Visualització       (387.0Kb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques