Mostra el registre parcial de l'element
dc.contributor.author | Barros, Luiz-Antônio-Borelli | es |
dc.contributor.author | da Silva, Caio-Fossalussa | es |
dc.contributor.author | Camargos, Germana-de Villa | es |
dc.contributor.author | Marcantonio Jr., Elcio | es |
dc.contributor.author | de Oliveira, Guilherme-José-Pimentel-Lopes | es |
dc.contributor.author | Barros-Filho, Luiz-Antônio-Borelli | es |
dc.date.accessioned | 2023-05-31T12:29:23Z | |
dc.date.available | 2023-05-31T12:29:23Z | |
dc.date.issued | 2022 | es |
dc.identifier.citation | Barros, L. A., da Silva, C. F., Camargos, G. V., Marcantonio, E., Jr, de Oliveira, G. J., & Barros-Filho, L. A. (2022). In vitro evaluation of the influence of bone cortical thickness on the primary stability of conventional- and short-sized implants. Journal of clinical and experimental dentistry, 14(2), e138–e143. | es |
dc.identifier.uri | https://hdl.handle.net/10550/87407 | |
dc.description.abstract | The aim of this in vitro study was to evaluate the influence of the cortical thickness on the primary stability of short and conventional-sized implants with two types of prosthetic connection. Seventy-two implants were used. These implants were placed | es |
dc.title | In vitro evaluation of the influence of bone cortical thickness on the primary stability of conventional- and short-sized implants | es |
dc.type | journal article | es_ES |
dc.subject.unesco | UNESCO:CIENCIAS MÉDICAS | es |
dc.identifier.doi | 10.4317/jced.58886 | es |
dc.type.hasVersion | VoR | es_ES |
dc.identifier.url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8842290/ |