Improving bleeding detector features for electron intraoperative radiotherapy

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Improving bleeding detector features for electron intraoperative radiotherapy

Mostra el registre parcial de l'element

dc.contributor.author Sanchis Peris, Enrique
dc.contributor.author Casans Berga, Silvia
dc.contributor.author García Gil, Rafael
dc.contributor.author Martos Torres, Julio
dc.contributor.author Sanchis Sánchez, Enrique
dc.contributor.author Pérez Calatayud, Ignacio
dc.contributor.author Pérez Calatayud, María José
dc.contributor.author Pérez Calatayud, José
dc.date.accessioned 2023-11-15T11:47:34Z
dc.date.available 2023-11-15T11:47:34Z
dc.date.issued 2019
dc.identifier.uri https://hdl.handle.net/10550/91167
dc.description.abstract Purpose: The aim of this work is to improve the potential bleeding detection during intraoperative radiotherapy with linac polymethyl methacrylate applicators (PMMA), based on one previously developed. The improvements carried out have been focused on: i) minimizing the impact of the detector on the visual through the plastic applicators and ii) avoiding the asymmetry in the detection capability when the applicator is tilted. Methods: Simulations have been made to select the geometry that provides a reduced visual impact on the applicator as well as allowing an independent response with the tilting angle of the applicator. A low-noise circuit for signal conditioning has been developed. Measurements have been made on three setups: 10 cm, 7 cm and 4 cm applicator diameters, 0° and 45° tilted. Results: The detector has a visibility through the applicator greater than 50%. Due to the geometry, optimal detection is ensured regardless of its orientation when the applicator is tilted. It is possible to detect the presence of fluid well below the typical perturbing fluid depth established by the clinic (1-1.5 cm). Conclusions: The detector can distinguish the presence of around 0.5 cm of fluid depth while showing a high visual field through the PMMA applicators and providing a measure that does not depend on the detector orientation when the applicator is tilted. The prototype is ready for its industrialization by embedding it into the applicator for clinical use. The detector would have a significant impact on both the quality assurance and the outcome of the treatment.
dc.language.iso eng
dc.relation.ispartof Physica Medica, 2019, vol. 65, p. 150-156
dc.source Sanchis Peris, Enrique, Casans Berga, Silvia, García Gil, Rafael, Martos Torres, Julio Sanchis Sánchez, Enrique, Pérez Calatayud, Ignacio, Pérez Calatayud, María José, Pérez Calatayud, José (2019). Improving bleeding detector features for electron intraoperative radiotherapy. Physica Medica, 65, 150 156. https://doi.org/10.1016/j.ejmp.2019.08.015
dc.subject electrònica
dc.subject electrònica aparells i instruments
dc.subject electrònica mèdica
dc.title Improving bleeding detector features for electron intraoperative radiotherapy
dc.type journal article
dc.date.updated 2023-11-15T11:47:34Z
dc.identifier.doi 10.1016/j.ejmp.2019.08.015
dc.identifier.idgrec 134018
dc.rights.accessRights open access