dc.description.abstract | Purpose: The aim of this work is to improve the potential bleeding detection during intraoperative radiotherapy with linac polymethyl methacrylate applicators (PMMA), based on one previously developed. The improvements carried out have been focused on: i) minimizing the impact of the detector on the visual through the plastic applicators and ii) avoiding the asymmetry in the detection capability when the applicator is tilted. Methods: Simulations have been made to select the geometry that provides a reduced visual impact on the applicator as well as allowing an independent response with the tilting angle of the applicator. A low-noise circuit for signal conditioning has been developed. Measurements have been made on three setups: 10 cm, 7 cm and 4 cm applicator diameters, 0° and 45° tilted. Results: The detector has a visibility through the applicator greater than 50%. Due to the geometry, optimal detection is ensured regardless of its orientation when the applicator is tilted. It is possible to detect the presence of fluid well below the typical perturbing fluid depth established by the clinic (1-1.5 cm). Conclusions: The detector can distinguish the presence of around 0.5 cm of fluid depth while showing a high visual field through the PMMA applicators and providing a measure that does not depend on the detector orientation when the applicator is tilted. The prototype is ready for its industrialization by embedding it into the applicator for clinical use. The detector would have a significant impact on both the quality assurance and the outcome of the treatment. | |
dc.language.iso | eng | |
dc.relation.ispartof | Physica Medica, 2019, vol. 65, p. 150-156 | |
dc.source | Sanchis Peris, Enrique, Casans Berga, Silvia, García Gil, Rafael, Martos Torres, Julio Sanchis Sánchez, Enrique, Pérez Calatayud, Ignacio, Pérez Calatayud, María José, Pérez Calatayud, José (2019). Improving bleeding detector features for electron intraoperative radiotherapy. Physica Medica, 65, 150 156. https://doi.org/10.1016/j.ejmp.2019.08.015 | |
dc.subject | electrònica | |
dc.subject | electrònica aparells i instruments | |
dc.subject | electrònica mèdica | |
dc.title | Improving bleeding detector features for electron intraoperative radiotherapy | |