Mostra el registre parcial de l'element
dc.contributor.author | Attié, D. | |
dc.contributor.author | Cordier, B. | |
dc.contributor.author | Gros, M. | |
dc.contributor.author | Laurent, Ph. | |
dc.contributor.author | Schanne, S. | |
dc.contributor.author | Tauzin, G. | |
dc.contributor.author | von Ballmoos, P. | |
dc.contributor.author | Bouchet, L. | |
dc.contributor.author | Jean, P. | |
dc.contributor.author | Knödlseder, J. | |
dc.contributor.author | Mandrou, P. | |
dc.contributor.author | Paul, Ph. | |
dc.contributor.author | Roques, J. P. | |
dc.contributor.author | Skinner, G. | |
dc.contributor.author | Vedrenne, G. | |
dc.contributor.author | Georgii, R. | |
dc.contributor.author | von Kienlin, A. | |
dc.contributor.author | Lichti, G. | |
dc.contributor.author | Schönfelder, V. | |
dc.contributor.author | Strong, A. | |
dc.contributor.author | Wunderer, C. | |
dc.contributor.author | Shrader, C. | |
dc.contributor.author | Sturner, S. | |
dc.contributor.author | Teegarden, B. | |
dc.contributor.author | Weidenspointner, G. | |
dc.contributor.author | Kiener, J. | |
dc.contributor.author | Porquet, M. G. | |
dc.contributor.author | Tatischeff, V. | |
dc.contributor.author | Crespin, S. | |
dc.contributor.author | Joly, S. | |
dc.contributor.author | André, Y. | |
dc.contributor.author | Sánchez Martínez, Filomeno | |
dc.contributor.author | Leleux, P. | |
dc.date.accessioned | 2010-06-29T10:59:40Z | |
dc.date.available | 2010-06-29T10:59:40Z | |
dc.date.issued | 2003 | |
dc.identifier.citation | ATTIÉ, D. et al. 2003, INTEGRAL/SPI ground calibration, Astronomy and Astrophysics, vol. 411, no. 1, p. L71–L79 | en |
dc.identifier.uri | http://hdl.handle.net/10550/14007 | |
dc.description.abstract | Three calibration campaigns of the spectrometer SPI have been performed before launch in order to determine the instrument characteristics, such as the e ective detection area, the spectral resolution and the angular resolution. Absolute determination of the e ective area has been obtained from simulations and measurements. At 1 MeV, the e ective area is 65 cm^2 for a point source on the optical axis, the spectral resolution 2.3 keV. The angular resolution is better than 2.5 and the source separation capability about 1º. Some temperature dependant parameters will require permanent in-flight calibration. | en |
dc.language.iso | en | en |
dc.subject | Instrumentation ; Detectors ; Spectrographs ; Space vehicles ; Gamma rays ; Observations | en |
dc.title | INTEGRAL/SPI ground calibration | en |
dc.type | journal article | es_ES |
dc.subject.unesco | UNESCO::ASTRONOMÍA Y ASTROFÍSICA | en |
dc.subject.unesco | UNESCO::ASTRONOMÍA Y ASTROFÍSICA::Astronomía óptica | en |
dc.identifier.doi | 10.1051/0004-6361:20031302 | en |
dc.type.hasVersion | VoR | es_ES |
dc.identifier.url | http://www.aanda.org/articles/aa/pdf/2003/43/aaINTEGRAL25.pdf | en |