NAGIOS: RODERIC FUNCIONANDO

An in vitro evaluation of two dentine adhesive systems to seal the pulp chamber using a glucose penetration model

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

An in vitro evaluation of two dentine adhesive systems to seal the pulp chamber using a glucose penetration model

Mostra el registre parcial de l'element

dc.contributor.author González Castillo, Silvia es
dc.contributor.author Bailón Sánchez, Mª Estela es
dc.contributor.author González Rodríguez, Mª Paloma es
dc.contributor.author Poyatos Martínez, Rafael es
dc.contributor.author Ferrer Luque, Carmen María es
dc.date.accessioned 2017-07-26T11:19:29Z
dc.date.available 2017-07-26T11:19:29Z
dc.date.issued 2011 es
dc.identifier.citation González Castillo, Silvia ; Bailón Sánchez, Mª Estela ; González Rodríguez, Mª Paloma ; Poyatos Martínez, Rafael ; Ferrer Luque, Carmen María. An in vitro evaluation of two dentine adhesive systems to seal the pulp chamber using a glucose penetration model. En: Medicina oral, patología oral y cirugía bucal. Ed. inglesa, 16 4 2011: 19- es
dc.identifier.uri http://hdl.handle.net/10550/60117
dc.description.abstract Objectives: To evaluate the sealing capability of Cavit TM G with or without Clearfil TM S3 Bond and Prime & Bond NT placed in the pulp chamber. Study Design: Forty single rooted premolars, extracted for orthodontic and periodontal reasons, with intact coronal surface and mature apices, were standardized to a length of 15 mm. The teeth were instrumented, filled with a gutta-percha master cone and divided into three groups to obturate the pulp chambers: Cavit TM G; Clearfil TM S3 Bond plus Cavit TM G and Prime & Bond® NT plus Cavit TM G. A glucose leakage model was used for evaluating the coronal microleakage. The Mann-Whitney test was used to evaluate the differences in the means of the glucose leakage. Results: An increase in glucose penetration was observed during the first week in groups Cavit TM G and Cavit TM G+PBNT. The glucose penetration values of all groups were similar at 30 and 45 days, and there were no significant differences among them in both time periods (p=0.736 and p=0.581, respectively). Conclusions: The adhesive systems did not improve the capability of Cavit TM G to seal the pulp chamber over time © Medicina Oral S. L. es
dc.title An in vitro evaluation of two dentine adhesive systems to seal the pulp chamber using a glucose penetration model es
dc.type journal article es_ES
dc.subject.unesco UNESCO::CIENCIAS MÉDICAS es
dc.identifier.doi 10.4317/medoral.16.e556 es
dc.type.hasVersion VoR es_ES

Visualització       (442.9Kb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques