NAGIOS: RODERIC FUNCIONANDO

Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant?retained overdentures

Repositori DSpace/Manakin

IMPORTANT: Aquest repositori està en una versió antiga des del 3/12/2023. La nova instal.lació está en https://roderic.uv.es/

Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant?retained overdentures

Mostra el registre parcial de l'element

dc.contributor.author El Mekawy, Nesreen es
dc.contributor.author Elhawary, Mohamed-Yosry es
dc.date.accessioned 2019-03-07T11:34:41Z
dc.date.available 2019-03-07T11:34:41Z
dc.date.issued 2019 es
dc.identifier.citation El Mekawy, Nesreen ; Elhawary, Mohamed-Yosry. Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant?retained overdentures. En: Journal of Clinical and Experimental Dentistry, 11 1 2019: 33-41 es
dc.identifier.uri http://hdl.handle.net/10550/69427
dc.description.abstract This study was aimed to evaluate the influence of inter-implant distance on the wear characteristics of low-profile stud attachments used in mandibular implant retained overdentures. Forty Completely edentulous participants aged between 50 ? 70 years were enrolled in this study. Each patient received 2-implants by 2-stage submerged surgical protocol. Participants categorized into 4-groups. Group I: 19 mm inter-implant distance with Locator retained overdentures; Group II: 19 mm inter-implant distance with OT Equator retained overdentures; Group III: 25 mm inter-implant distance with Locator retained overdentures; Group IV: 25 mm inter-implant distance with OT Equator retained overdentures. The female housings of each attachment were picked up to the mandibular overdenture. 12 month later the male inserts were replaced by new one. The used retentive male inserts were examined by Stereomicroscopic. Stereomicroscopic examination revealed wear were detected on both inner surface and, the core of male inserts. Comparison between the unused and the used Locator and OT equator retentive male inserts at various inter-implant distance revealed highly significant wear changes between them at either 19 mm, or 25 mm inter-implant distance P1= .000, P2=.000 respectively. After one year of implant overdenture clinical use; both locator and OT equator retentive male inserts revealed significant surface deformities and wear. Wear were more notable on both locator and OT equator retentive male inserts with 25 mm interimplant distance than with 19 mm interimplant distance. es
dc.title Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implant?retained overdentures es
dc.type journal article es_ES
dc.subject.unesco UNESCO::CIENCIAS MÉDICAS es
dc.identifier.doi 10.4317/jced.55433 es
dc.type.hasVersion VoR es_ES

Visualització       (1.187Mb)

Aquest element apareix en la col·lecció o col·leccions següent(s)

Mostra el registre parcial de l'element

Cerca a RODERIC

Cerca avançada

Visualitza

Estadístiques